INST 385 E35 SALT CHLORINE GENERATOR (10-2018)
8
SALT CHLORINE GENERATOR MAINTENANCE AND TROUBLESHOOTING
If the supply cord is damaged, it must be replaced by AstralPool or its service agent or a similarly qualified person in
order to
avoid a hazard.
WARNING: Operating the Salt Chlorine Generator with less than 3,000 ppm of dissolved salt in the water may
cause damage to the cell and will void the warranty. Never start Salt Chlorine Generator, until the correct quantity
of salt has been added and dissolved in your pool water.
Cell Maintenance
Your E35 Salt Chlorine Generator has an automatic cleaning feature that, under normal conditions, will keep the cell
plates clear of deposits of salt and calcium.
E35 Salt Chlorine Generator cells have a negative charge sensor that monitors the flow and salt levels of the water. This
sensor is designed to be fail-safe. As it is negative charge sensor, deposits of calcium or other debris may be deposited
on it and cause it to indicate a low salt or no flow condition. Should a low salt condition be indicated, have your salt level
checked at your local pool shop. If the low salt condition persists, or a no flow condition is indicated when the supply
pump is operating, you may need to manually clean your Salt Chlorine Generator Cell.
Cell Cleaning Instructions:
Close applicable valves.
Disconnect the Salt Chlorine Generator from the Mains by a circuit breaker.
Disconnect the cell wires.
Undo the barrel nuts connecting the cell to your filtration system.
Turn the cell upside down (inlet and outlet on top) and fill the cell with a cell cleaning solution, sold at your pool
retailer.
Repeat if necessary and then rinse well in clean water.
Reinstall the cell ensuring O-rings are correctly located and barrel nuts are tightened to prevent leaks.
Reconnect cell wires with wing nuts supplied making sure the blue wire is connected to the blue terminal.
Incorrect connection may damage your Salt Chlorine Generator control. Tighten wing-nuts to ensure the
electrical connection is sound.
Return all valves to their normal positions; reconnect power at the circuit breaker.
WARNING: Follow safety instructions provided with the cell cleaning solution. The use of eye protection, mask