115C and 117C
Users Manual
20
Certifications ............................................................UL, P, CSA, TÜV, ;
(N10140), VDE
IP Rating (dust and water protection) ......................... IP42
Table 1. Accuracy Specifications
Function Range Resolution
Accuracy
± ([% of Reading] + [Counts])
Model
DC millivolts 600.0 mV 0.1 mV 0.5 % + 2
115C,
117C
DC Volts
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 2
115C,
117C
DC, 45 to 500 Hz 500 Hz to 1 kHz
Auto-V LoZ
[1]
True-rms 600.0 V 0.1 V
2.0 % + 3 4.0 % + 3
117C
45 to 500 Hz
500 Hz to 1 kHz
AC millivolts
[1]
True-
rms
600.0 mV 0.1 mV
1.0 % + 3
2.0 % + 3
115C,
117C
AC Volts
[1]
True-rms
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3
2.0 % + 3
115C,
117C