2 Fluke Corporation Fluke 1587/i400 Current Clamp FC Kit
https://www.fluke.com/th-th/product/electrical-testing/insulation-testers/fluke-1587-i400-fc-kit
Use with your Fluke 1587 FC to measure 1A AC to 400 A AC
1 mA/Amp output guarantees easy reading
CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
Specially designed to offer maximum utility in a very compact shape
Maximum conductor: Ø 32 mm
1 year warranty
ภาพรวมผลิตภัณฑ์: Fluke 1587/i400 Current Clamp FC Kit
Includes the 1587 FC 2-in-1 Insulation DMM and the i400 Current Clamp
The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect
Measurements app:
Pl/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical
tracking over time
Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the
field with Fluke Connect® Assets
The Fluke i400 AC CurrentClamp is a high-safety current clamp for digital multimeters. The current clamp provides
accurate current measurements without breaking electric circuits, helping you take measurements safely with industry
standard safety ratings.
ข้อมูลจำเพาะ: Fluke 1587/i400 Current Clamp FC Kit
Fluke 1587 FC Insulation Multimeter
Electrical Specifications
AC voltage measurement
Range
600.0 mV
Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg
+ Counts)
±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of
Rdg + Counts)
±(2% + 3)
6.000 V
Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg
+ Counts)
±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of
Rdg + Counts)
±(2% + 3)
60.00 V
Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg
+ Counts)
±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of
Rdg + Counts)
±(2% + 3)

Other manuals for Fluke 1587