Fluke 15B+ - Accuracy Specifications

Fluke 15B+
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Digital Multimeters
Accuracy Specifications
19
Accuracy Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to
75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
AC and DC Voltage
Function Range Resolution
Accuracy
15B+ 17B+ 18B+
AC Volts (40 Hz – 500 Hz)
[1]
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 3 1.0 % + 3
1.0 % + 3
AC Millivolts
400.0 mV 0.1 mV 3.0 % + 3 3.0 % + 3
3.0 % + 3
DC Millivolts
400.0 mV 0.1 mV 1.0 % + 10 1.0 % + 10
1.0 % + 10
DC Volts
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5 % + 3 0.5 % + 3
0.5 % + 3
[1] All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.