EasyManuals Logo

Fluke 325 Calibration Manual

Fluke 325
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
323/324/325
Calibration Manual
2
Safety Information
A Warning identifies conditions and procedures that are dangerous to the user. A
Caution identifies conditions and procedures that could cause Product damage,
equipment under test damage, or permanent loss of data.
Table 1 shows the symbols used on the Product and in this manual.
Warning
To prevent possible electrical shock, fire, or personal injury:
Use the Product only as
specified, or the protection
supplied b
y
the Product can be compromised.
Use onl
y correct measurement category
(CAT), voltage, and
amperage rated probes, test leads, and adapters for the
measurement.
Do not touch voltages > 30 V ac rms, 42 V ac peak, or
60 V dc.
Carefull
y re
ad all instructions.
Hold the Product behind the tactile barrier. See Figure 1,
item .
Do not exceed the Measurement Category
(CAT) rating
of
the lo
w
est rated individual component of a Product, probe,
or accessory
.
Do not measure current while the t
est leads are in the input
jacks.
Do not use the Product around explosive gas, vapor, or in
damp or w
e
t environments.
Limit operation to the specified measurement category
,
voltage, or amperage ratings.
Do not w
ork
alone.
Do not apply
more than the rated voltage, between
the
terminals or betw
een e
ach terminal and earth ground.
Compl
y with local and national safety codes.
Use personal
protective equipment (approved rubber gloves, face
protection, and flame-resistant clothes) to prevent shock
and arc blast injury
w
here hazardous live conductors are
exposed.
Replace the batteries w
hen the low battery indicator shows
to prevent incorrect m
easurements.
The battery
door must be closed and locked before y
ou
operate the Product.
Measure a
known volt
age first to make sure that the Product
operates correctl
y.
Remove all probes, test leads, and accessories that are not
necessary for the measurement.
Onl
y use pr
obes, test leads, and accessories that have the
same measurement category
and
voltage rating as the
Product.
Keep fingers behind the finger guards on the probes.

Other manuals for Fluke 325

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 325 and is the answer not in the manual?

Fluke 325 Specifications

General IconGeneral
AC voltage600 V
Continuity30 Ω
Resistance (max)40000 Ω
Resistance (min)40 Ω
Measuring categoryCAT III 600V, CAT IV 300V
AC current maximum resolution (probe)400 A
Product colorBlack, Red, Yellow
Carrying caseYes
Weight and Dimensions IconWeight and Dimensions
Depth34 mm
Width75 mm
Height207 mm
Weight283 g