EasyManua.ls Logo

Fluke 355 User Manual

Fluke 355
3 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Technical Data
Fluke 355/353
True-rms 2000 A Clamp Meters
High current and
a large jaw, make
these clamps
well suited for
industrial and
utility applications
Confidently take reliable readings
with the true-rms, Fluke 355/353
Clamp Meters; the tools of choice
for high-current measurements
up to 2000 A. The extra-wide
jaw easily clamps around large
conductors typically found in high-
current applications. The rugged
design and CAT IV 600 V, CAT III
1000 V ratings, add an extra ele-
ment of protection when taking
high-powered measurements.
Accurate peak measurements
can be taken using the in-rush
current mode, ideal for motors
and inductive loads. The 355 also
measures voltage and resistance,
making this the most versatile tool
for utilities, electrical contractors,
and industrial service technicians.
Reliably handle a wide range of high-current
applications with 2000 A ac + dc true-rms,
1400 A ac, and 2000 A dc
The large 58 mm (2.3 in) jaw capacity is suitable for
large, or multiple conductors
CAT IV 600 V, CAT III 1000 V rating for added user
protection
In-rush current measurement captures ‘power-on’
surge current with accuracy and repeatability
High voltage measurement of 1000 V ac + dc
true-rms, 600 V ac, and 1000 V dc allows users to
perform multiple tests with only one tool (355 only)
Resistance to 400 kW coupled with a continuity
beeper, provide the convenience of a multimeter
(355 only)
Accurately measure frequency up to 1 kHz for
optimum troubleshooting
Quickly analyze readings using the MIN, MAX, and
AVG functions
A large backlit display allows for easy visibility in
low-lit areas
Use the display hold feature to capture readings
even when the display cannot be viewed
Use the low-pass filter to smooth out noisy loads
and stabilize readings
N10140
Question and Answer IconNeed help?

Do you have a question about the Fluke 355 and is the answer not in the manual?

Fluke 355 Specifications

General IconGeneral
AC voltage600 V
DC voltage1000 V
Low pass filterYes
DC current (max)2000 A
Resistance (max)400000 Ω
Resistance (min)4000 Ω
Measuring categoryCAT III 1000V, CAT IV 600V
AC voltage resolution (min)0.001 V
AC current maximum resolution (probe)1 A
CertificationIEC 61010-2-032, CE, RoHS, EMI, RFI, EMC, IP42
Product colorBlack, Red, Yellow
Battery typeAA
Number of batteries supported6
Operating altitude0 - 2000 m
Non-operating altitude0 - 10000 m
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth52 mm
Width98 mm
Height300 mm
Weight814 g

Summary

Product Overview and Features

High Current and Large Jaw Capacity

Well suited for industrial and utility applications due to large jaw size.

True-rms Measurement Capabilities

Confidently take reliable readings up to 2000 A with true-rms measurements.

In-rush Current Measurement

Captures 'power-on' surge current with accuracy and repeatability.

High Voltage Measurement

Measures up to 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc.

Safety Ratings

CAT IV 600 V, CAT III 1000 V ratings for added user protection.

Electrical Specifications

Current Measurement DC and AC (10 Hz to 100 Hz)

Details DC and AC current measurement ranges, resolution, accuracy, and trigger levels.

Crest Factor (50/60 Hz)

Specifies crest factor limits for different current ranges at 50/60 Hz.

Current Measurement AC (100.1 Hz to 1 kHz)

Details AC current measurement ranges, resolution, accuracy, and trigger levels.

Voltage Measurement DC and AC (10 Hz to 100 Hz) - 355 Only

Specifies DC and AC voltage measurement ranges, accuracy, and trigger levels.

Voltage Measurement AC (100.1 Hz to 1 kHz) - 355 Only

Details AC voltage measurement ranges, accuracy, and trigger levels for frequencies above 100 Hz.

Ohms Measurement - 355 Only

Specifies resistance measurement ranges, resolution, and accuracy.

Other Specifications and Details

Continuity Beeper (355 Only)

Defines the operating thresholds for the continuity beeper.

Frequency Measurement

Details the measurement range, resolution, accuracy, and trigger level for frequency.

General Specifications

Covers batteries, test leads, weight, jaw size, dimensions, and safety ratings.

Environmental Specifications

Outlines operating/storage temperature, humidity, altitude, IP rating, and EMC compliance.

Ordering Information

Fluke-353 Model

Details what is included with the Fluke-353 AC/DC True-rms Clamp Meter.

Fluke-355 Model

Lists included accessories for the Fluke-355 AC/DC True-rms Clamp Meter.