365
Users Manual
Ha
ve the Meter serviced only by qualified service personnel
.
Be careful around voltages >30 V ac rms, 42 V ac peak, or 60 V dc. Such voltages
pose a
shock h
azard.
Do
not apply more than the rated voltage, as marked on the Meter, between
the
terminals or between any terminal and earth ground.
W
hen using the probes, keep fingers behind the finger guards on the probes.
Connect the common test lead before connecting the live test lead. When
disconnecting test leads, disconnect the live test lead first.
Do n
ot work alone so assistance can be rendered in an emergency.
Use extreme caution when working around bare conductors or bus bars. Cont
act
with the conductor could result in electric shock.
A
dhere to local and national safety codes. Individual protective equipment must
be used to prevent shock and arc blast injury where hazardous live conduc
tors
are exposed.
Disco
nnect circuit power and discharge all high-voltage capacitors before yo
u
do di
ode tests or measure resistance or continuity
.
Do not measure ac/dc current in circuits carrying more than 600 V or 200 A with
the Me
ter Jaw.
Never operate the Meter with the back cover removed or the case ope
n.