Clamp Meters
Specifications
19
Specifications
Electrical Specifications
AC Current via Jaw
Range
374 and 375 ......................................600.0 A
376.....................................................999.9 A
Resolution ...............................................0.1 A
Accuracy .................................................2 % ± 5 digits (10-100 Hz)
2.5 % ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) ..........................3 @ 500 A (375 and 376 only)
2.5 @ 600 A
1.42 @1000 A (376 only)
Add 2 % for C.F. > 2