Specifications continued
General
Case
Design Rugged, shock proof with integrated protective holster
Drip and dust proof IP51 according to IEC60529 when used in tilt stand position
Shock and Vibration Shock 30 g, Vibration: 3 g Sinusoid, Random 0.03 g
2
/Hz according to MIL-PRF-28800F Class 2
Display
Type Bright Full-Color LCD with CCFL backlight, 80cd/m
2
Size 115.2 x 86.4 mm (4.5 x 3.4 in)
Resolution 320 x 240 pixels
Contrast and brightness User adjustable, temperature compensated
Memory
Screens 50 screen memories on Fluke 434
25 screen memories on Fluke 433
Data 10 data memories for storing data including recordings on Fluke 434
5 data memories for storing data including recordings on Fluke 433
Limit templates 2 preprogrammed, 2 administrator (programmable via FlukeView, 2 user locations)
Real-time clock Time and date stamp for AutoTrend, Transient display and SystemMonitor
Mechanical
Size 256 x 169 x 64 mm (10 x 6.6 x 2.5 in.)
Weight 2 kg (4.4 lb.)
Power
Line power Switchable 115 V, 230 V adapter with country specific plug
Battery power Rechargeable NiMH (installed)
Battery operating time > 7 hours
Battery charging time 4 hours
Power saving Adjustable time for dimmed backlight with on screen power indicator
Standards
Measurement methods used IEC61000-4-30 class A
Power Quality EN50160
Flicker IEC 61000-4-15
Harmonics IEC 61000-4-7
Safety
Compliance IEC/EN61010-1 (2nd edition) pollution degree 2; CAN/CSA C22.2 No 101.1; ANSI/ISA S82.01
Max voltage on banana input CAT III 1000 V / CAT IV 600 V
Max voltage on current B
N
C input 42 Vpeak
Environmental
Operating temperature 0 °C to +50 °C (32 °F to 122 °F)
Storage temperature -20 °C to +60 °C (-4 °F to 140 °F)
Humidity 10 to 30 °C: 95 % RH non condensing (50 to 86 °F: 95 % RH non condensing)
30 to 40 °C: 75 % RH non condensing (86 to 104 °F: 75 % RH non condensing)
40 to 50 °C: 45 % RH non condensing (104 to 122 °F: 45 % RH non condensing)
Maximum operating altitude 3000 m (9842 ft) Derate to CAT II 1000 V / CAT III 600 V / CAT IV 300 V above 2000 m (6561 ft)
Maximum storage altitude 12 km (39,372 ft)
Warranty 3 years on mainframe, 1 year on included accessories
Accessories
Included Hard carrying case with clamp holders BC430
4 current clamps, i400s
5 Test leads, 4 black, 1 green
5 Alligator clips, 4 black, 1 green
Battery Charger Eliminator, BC430
FlukeView Software, SW43W (Fluke 434 only)
Optical Cable for USB , OC4USB (Fluke 434 only)
Color localization set, WC100
Getting Started (printed)
User Manual (CD-ROM)
1
depending clamp scaling
2
50 Hz/60 Hz nominal frequency according to IEC 61000-4-30
3
Add clamp accuracy
4
The advanced functions: interharmonics, energy, transients and inrush are optional for the Fluke 433 and standard available on the Fluke 434
Fluke 430 Series Three-Phase Power Quality Analyzers Fluke Corporation 7

Related product manuals