EasyManua.ls Logo

Fluke 561 HVACPro - Specifications

Fluke 561 HVACPro
22 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
561 HVACPro
Users Manual
18
Specifications
Infrared
Measurement Range ................................................................-40 °C to 550 °C (-40 °F to 1022 °F)
Spectral Range .........................................................................8 to 14 microns
Accuracy...................................................................................± 1 % or ± 1 °C (2 °F); < 0 °C (32 °F),
± 1 °C (2 °F) ± 0.1°/1°
(Assumes ambient operating temperature
of 23 to 25 °C (73 to 77 °F))
Repeatability.............................................................................± 0.5 % of reading or ± 1°C (2 °F)
Response Time (95 %).............................................................500 ms
Distance to Spot (D:S)..............................................................12:1
Emissivity Adjustment..............................................................Three settings: low (0.3), medium (0.7),
high (0.95)
Contact Probe
Probe Type ...............................................................................Wrap thermocouple type K probe with
miniconnector
Measurement Range ................................................................0 °C to 100 °C (32 °F to 212 °F)
Probe Accuracy ........................................................................± 2.2 °C (4 °F)
Display Resolution....................................................................± 0.1 °C (0.1 °F)
Secondary Display Information ................................................Maximum, Minimum, Differential, KTC
Laser
Sighting....................................................................................Single point laser
Power .......................................................................................Class 2 (II) operation; Output <1 mW,
wavelength 630 to 670 nm
Electrical
Power Supply ...........................................................................2 AA Batteries (alkaline or NiCD)
Power Consumption.................................................................At least 12 hours battery life
Physical
Weight......................................................................................17.69 cm (6.965 in) H x 16.36 cm (6.441
in) L x 5.18 cm (2.039 in) W
Size...........................................................................................0.322 kg (0.7099 lb)
Total Length of Thermocouple .................................................Approximately 100 cm (40 in)
Environmental
Operating Temperature Range..................................................0 °C to 50 °C (32 °F to 120 °F)
Relative Humidity .....................................................................0 to 90 %, noncondensing up to 30 °C
(86 °F)
Storage Temperature................................................................- 20 °C to 65 °C (-4 °F to 150 °F)
Optional Accessories................................................................Soft Case