Testing the Ohms Function
1. Set the UUT to (ohms).
2. Connect the ohms calibrator or decade resistor to the VG and COM input terminals of the UUT.
3. Referring to Table 7, set the decade resistor or ohms calibrator to the resistance value indicated in steps
1 through 7. Verify that the display reading is within the limits shown.
Table 7. Resistance Test
Step Range Input Resistance Display Reading
1 400 short 0 to 0.2
Decades of 1:
2 400 100 99.4 to 100.6 (plus 0 reading)
34 k 1 k .995 to 1.005 k
4 40 k 10 k 9.95 to 10.05 k
5 400 k 100 k 99.3 to 100.7 k
64 M 1 M .995 to 1.005 M
7 40 M 10 M 9.87 to 10.13 M
Decades of 1.9:
2 400 190 189.0 to 191.0 (plus 0 reading)
34 k 1.9 k 1.891 to 1.909 k
4 40 k 19 k 18.91 to 19.09 k
5 400 k 190 k 188.8 to 191.2 k
64 M 1.9 M 1.891 to 1.909 M
7 40 M 19 M 18.78 to 19.22 M
Decades of 3.5:
2 400 350 348.4 to 351.6 (plus 0 reading)
34 k 3.5 k 3.485 to 3.515 k
4 40 k 35 k 34.85 to 35.15 k
5 400 k 350 k 347.8 to 352.2 k
64 M 3.5 M 3.485 to 3.515 M
7 40 M 35 M 34.62 to 35.38 M
Testing the Lo-Ohms Function
1. Switch the instrument function to the Lo-Ohm continuity position.
2. Place a short across the VG and COM input Terminals.
3. Push the RANGE button for 1 second to initiate Lo-Ohm calibration.
4. Push the RANGE button again to calibrate Lo-Ohms.
5. Apply 40 ohms to the VG and COM terminals and verify that the reading is within 38.00 to
42.00 .

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 79 III and is the answer not in the manual?

Fluke 79 III Specifications

General IconGeneral
CategoryMultimeter
Display TypeDigital
True RMSNo
Voltage DC1000V
Voltage AC750V
Current DC10A
Current AC10A
Resistance40MΩ
ContinuityYes
Diode TestYes
Battery Type9V
Resistance Range400Ω to 40MΩ
Display4000 count LCD
DC Voltage Range400 mV, 4 V, 40 V, 400 V, 1000 V
AC Voltage Range400 mV, 4 V, 40 V, 400 V, 750 V
DC Current Range10μA to 10A
AC Current Range10μA to 10A

Related product manuals