Series III Multimeter
Specifications
5
Table 1. Specifications (cont.)
Function Range Resolution Accuracy Burden Voltage (Typical)
? (45 Hz to 1 kHz) 4.000 mA 0.001 mA ±(1.5 %+4) 11 mV/mA
40.00 mA 0.01 mA ±(1.5 %+2) 11 mV/mA
4 A 0.001 A ±(1.5 %+4) 0.03 V/A
10.00 A* 0.01 A ±(1.5 %+2) 0.03 V/A
A 4.000 mA 0.001 mA ±(0.5 %+5) 11 mV/mA
40.00 mA 0.01 mA ±(0.5 %+2) 11 mV/mA
4 A 0.001 A ±(0.5 %+5) 0.03 V/A
10.00 A* 0.01 A ±(0.5 %+2) 0.03 V/A
Frequency** 99.99 0.01 Hz ±(0.01 %+1)
(1 Hz to 20 kHz) 999.9 0.1 Hz ±(0.01 %+1) Not Applicable
9.999 kHz 0.001 kHz ±(0.01 %+1)
20.00 kHz 0.01 kHz ±(0.01 %+1)
* Overload, 20 A for 30 seconds
** For rectangular waveforms 25 % duty cycle 75 % . V ac 1 kHz.
Frequency Counter Sensitivity and Trigger Level
Input Range* Minimum Sensitivity (RMS Sine Wave)
500 Hz to 20 kHz 1.0 Hz to 500 Hz**
400 mV ac Not Applicable Not Applicable
4 V ac 0.3 V 0.7 V
40 V ac 3 V 7 V
400 V ac 30 V 70 V
1000 V ac 300 V Not Applicable
* Maximum input for specified accuracy = 10 x Range or 600 V.
** Display rattle for sine waves below 500 Hz = 5 counts.
Function Overload
Protection*
Input Impedance
(Nominal )
Common Mode
Rejection Ratio
(1 k Unbalance)
Normal Mode
Rejection
L 1000 V dc
1000 V ac rms (sine)
>10 M,
<100 pF
>120 dB at dc,
50 Hz, or 60 Hz
>60 dB at 50 Hz
or 60 Hz
m
L 1000 V dc
1000 V ac rms (sine)
10 M,
<100 pF
>120 dB at dc,
50 Hz, or 60 Hz
>60 dB at 50 Hz
or 60 Hz
K 1000 V dc
1000 V ac rms (sine)
>10 M,
<100 pF
>60 dB, dc to
60 Hz
(ac-coupled)
e Open Circuit
Test Voltage
Full Scale Voltage Short Circuit Current
<4.0 M <40 M
1000 V dc,
1000 V rms (sine)
<1.3 V dc <450 mV dc <1.3 V dc <250 µA
G 1000 V dc,
1000 V rms (sine)
<3.1 V dc 2.45 V dc 600 µA typical
*10
7
V-Hz max.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 79 III and is the answer not in the manual?

Fluke 79 III Specifications

General IconGeneral
CategoryMultimeter
Display TypeDigital
True RMSNo
Voltage DC1000V
Voltage AC750V
Current DC10A
Current AC10A
Resistance40MΩ
ContinuityYes
Diode TestYes
Battery Type9V
Resistance Range400Ω to 40MΩ
Display4000 count LCD
DC Voltage Range400 mV, 4 V, 40 V, 400 V, 1000 V
AC Voltage Range400 mV, 4 V, 40 V, 400 V, 750 V
DC Current Range10μA to 10A
AC Current Range10μA to 10A