FL.UKE~
Instruction Sheet
80i-600
AC Current Probe
INTRODUCTION
The Model 80i-600 is a clamp-on
ac
current probe designed
to extend the current
me<lsuring
c<lp<lbility
of
an
ac current
meter to 600 amperes. A clamp-on, 1000-turn coil designed
into the probe allows measurements to be made
without
breabng
the circuit under test. The coil serves as the second-
ary
of
a current transformer. Thecurrent carrying conductor
being measured serves as the primary. Because
of
a high
efficiency, quadrature type
of
winding used. wire size ,md
the position
of
the wire within the prohe
jaws
does not effect
accuracy.
SPECIFICATIONS
Input Current Range: I A
to
600A
Output: I milli<lmp per ampere
of
input current
(1
mAl
A)
Accuracy: Accuracy:
±Y;
of
rcadiJ)~.
:,U
HI
tn
I
KHI.
±39'0
of
reading (typical).
30
Hz
to
5U
HI
or I
KHI
to
10
KHz.
Working Voltage: 750Y
ac
nns maximum
Maximum Conductor Size: 50.8 nml
(2
inch.)
Shunt (load) Resistance: less than
12
ohms at multim-
eter input to maintain specified accuracy
Typical Bandwidth: -10% at
10
Hz and 50 kHz
(lA,
400
Hz reference, excludes multimeter response)
Usable Current Range:
O.I{\.
to 2000A, 5 seconds
Ill<lxi-
mum above 600A
Safety: Protection Class Class
II
as
defined in IEC 348 and
ANSI
09.5
MULTIMETER COMPATIBILITY
The 80i-600
is
compatible with any multimeter capable
of
reading ac current equal to 111000
of
the current to
be
measured.
To
take full advantage
of
the
probe's
accuracy, a
multimeter ac current accuracy
of
±O.75%
or
better is
recommended. A voltmeterfitted with an external shunt will
qualify as a suitable current meter. However, to ensure
the
probe'saccuracy, the shunt(or multimeterinput resistance in
ac current) should be less than
12
ohms. This requirement is
met on Fluke
DMM'
s when using a current range
of
20 mA
or
greater.
Advanced Test Equipment Rentals
www.atecorp.com 800-404-ATEC (2832)
®
E
s
t
a
b
l
i
s
h
e
d
1
9
8
1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 80i-600 and is the answer not in the manual?

Fluke 80i-600 Specifications

General IconGeneral
Current Range1 A to 600 A AC
Output Voltage1 mV/A
Maximum Voltage600 V AC rms
Power Supply9 V battery
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Safety RatingCAT III 600 V
CategoryCurrent Probe
Output ConnectorBNC
Weight230 g