EasyManuals Logo

Fluke 8808A Datasheet

Fluke 8808A
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Fluke 8808A Digital Multimeter Extended Specifications Fluke Corporation 7
6 Fluke Corporation 8808A
Frequency
Gate Time...................................................................131 ms
Measurement Method .............................................AC-coupled input using the ac voltage measurement function.
Settling Considerations..........................................When measuring frequency after a dc offset voltage change, errors
may occur. For the most accurate measurement, wait up to 1 second to
allow input blocking RC time constant to settle.
Measurement Considerations ...............................To minimize measurement errors, shield inputs from external noise
when measuring low voltage, low frequency signals.
Accuracy
Accuracy
90 days 1 year
Range Frequency
23 °C ± 5 °C 23 °C ± 5 °C
Temperature
Coefficient/°C
Outside 18 – 28 °C
20 Hz – 2 kHz 0.01 + 0.002 0.01 + 0.003 0.002 + 0.001
2 kHz – 20 kHz 0.01 + 0.002 0.01 + 0.003 0.002 + 0.001
20 kHz – 200 kHz 0.01 + 0.002 0.01 + 0.003 0.002 + 0.001
100 mV to
750 V
[1,2]
200 kHz – 1 MHz 0.01 + 0.004 0.01 + 0.006 0.002 + 0.002
Notes:
[1] Input > 100 mV
[2] Limited to 8* 10
7
V Hz
Continuity
Continuity Threshold ..............................................20
Test Currents ............................................................1 mA
Response Time ........................................................100 samples/sec with audible tone
Rate…….…………………………………………… Fast
Maxiumum Reading………………………………199.99
Resolution……….….. ……………….……………0.01
Diode Test
Response Time.........................................................100 samples/sec with audible tone
Rate………………………………………………….Fast
Maxiumum Reading………………………..….…1.9999 V
Resolution….………..….. ………………………..0.1 mV

Other manuals for Fluke 8808A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 8808A and is the answer not in the manual?

Fluke 8808A Specifications

General IconGeneral
Product typeDigital multimeter
Product colorGrey, White
Frequency range0.2 - 2 kHz
AC current range0.2 - 10 A
AC voltage range0.2 - 750 V
DC current range0.0002 - 10 A
DC voltage range0.2 - 1000 V
Resistance range200 - 100000000 Ω
Placement supportedBench multimeter
Resistance resolution0.001 Ω
Resolution (frequency)0.0001 Hz
Resolution (AC current)100 µA
Resolution (DC current)1 µA
Resolution (DC voltage)1 mV
Basic accuracy (frequency)0.01%
Basic accuracy (DC current)0.02 + 0.005
Basic accuracy (DC voltage)0.015 + 0.003
Basic accuracy (resistance)0.02 + 0.003
Display digits5.5 digits
Weight and Dimensions IconWeight and Dimensions
Depth297 mm
Width217 mm
Height88 mm
Weight2100 g