Do you have a question about the Fluke 87V and is the answer not in the manual?
Diode test | Yes |
---|---|
AC current range | 0 - 10 A |
DC voltage range | 0 - 1000 V |
Resistance range | 0 - 50000000 Ω |
Capacitance range | 0 - 9.999 nF |
Resistance resolution | 0.1 Ω |
Resolution (frequency) | 0.1 Hz |
Resolution (AC current) | 0.1 µA |
Temperature measurement range | -200 - 1090 °C |
Dimensions (WxDxH) | 98 x 52 x 201 mm |
Weight | 355 g |
---|
Options activated by holding a button while turning the Meter on.
Meter automatically turns off after 30 minutes of inactivity.
Warns user if test leads are in wrong terminals for measurement.
Enables zoom for bar graph, activated during power-up.
Enters 4-1/2 digit high-resolution mode for Model 87.
Records minimum and maximum input values and calculates average.
Provides a steadier reading on the display for rapidly changing signals.
Captures stable readings, beeps and displays new stable readings.
Stores a reading as reference, zeros display, subtracts reference from subsequent readings.
Describes how to measure AC and DC voltages using the meter.
Explains residual AC readings and their impact on accuracy.
Describes the AC low pass filter for blocking unwanted voltages above 1 kHz.
Instructions for measuring temperature using a type-K thermocouple.
How to use the continuity test feature, including beeper function.
Explains how the meter measures resistance and its ranges.
Measures conductance (inverse of resistance) for high resistance tests.
Instructions for measuring capacitance and its ranges.
How to test diodes and interpret readings.
Procedures for measuring AC and DC current, including terminal usage.
Explains how the meter measures frequency and its ranges.
How to measure duty cycle (percentage of time signal is high/low).
Formula and steps to calculate pulse width from duty cycle and frequency.
Describes the analog bar graph function and its uses.
Instructions for cleaning the meter and its terminals.
How to test the meter's fuses and identify a bad fuse.
Steps for replacing the 9V battery.
Detailed steps for replacing internal fuses.
Information on obtaining replacement parts and troubleshooting.
Comprehensive specifications covering accuracy, operating conditions, and dimensions.