Do you have a question about the Fluke 87V MAX and is the answer not in the manual?
Waterproof | Yes |
---|---|
Product type | Digital multimeter |
Product color | Yellow |
Frequency range | 0.5 - 199.99 kHz |
DC voltage range | 0.1 - 1000 V |
Resistance range | 0.1 - 50 Ω |
Capacitance range | 0.1 - 9999 nF |
Measuring category | CAT III 1000V |
Placement supported | Handheld multimeter |
Resistance resolution | 0.1 Ω |
Resolution (frequency) | 0.01 Hz |
Resolution (AC current) | 0.1 µA |
Resolution (DC voltage) | 0.1 mV |
Temperature measurement range | -200 - 1090 °C |
International Protection (IP) code | IP67 |
Battery life | 800 h |
Battery type | AA |
Power source | Battery |
Number of batteries supported | 3 |
Depth | 215 mm |
---|---|
Width | 600 mm |
Height | 101 mm |
Weight | 698.5 g |
Describes the meter's display icons and their meanings.
The meter automatically turns off if no switch or button is pressed for 30 minutes.
Warns user with beeper and flashing display if test leads are in current terminals but switch is not set correctly.
Holding a button while turning the meter on activates a power-up option.
Describes how to measure AC and DC voltage using the meter.
Describes the low-pass filter for AC voltage and frequency measurements.
Explains how to measure temperature using a type-K thermocouple.
Explains how to measure conductance for high resistance and leakage tests.
Explains how to determine pulse width using frequency and duty cycle measurements.
Explains how to enable smoothing for steadier readings on rapidly changing inputs.
Explains how to zero the display and store a reference value for subsequent readings.
Details how to clean the meter case and terminals.
Describes how to test the meter's fuses using resistance measurement.
Provides instructions and safety warnings for replacing the meter's batteries.
Explains how to examine and replace the meter's fuses.
Provides detailed specifications for AC voltage measurements, including accuracy.
Details specifications for DC voltage, conductance, and resistance measurements.
Lists accuracy and resolution specifications for temperature measurements.
Provides detailed specifications for AC current measurements.
Lists accuracy, resolution, and burden voltage for DC current measurements.
Provides accuracy and resolution specifications for capacitance measurements.
Lists accuracy and resolution specifications for diode tests.
Details accuracy and resolution for frequency measurements.
Specifies sensitivity and trigger levels for frequency counter function.
Provides accuracy for duty cycle measurements.
Lists overload protection, input impedance, and CMRR for different functions.
Details accuracy specifications for MIN MAX recording modes.