Digital Multimeter
Features
7
gaq101.emf
Figure 1. Display Features
Table 4. Display Features
Number Feature Indication
Polarity indicator for the analog
bargraph.
Trig±
Positive or negative slope indicator
for Hz/duty cycle triggering.
The continuity beeper is on.
Relative (REL) mode is active.
Smoothing is active.
Number Feature Indication
-
Negative readings, In relative mode,
this sign indicates that the present
input is less than the stored
reference.
High voltage present at the input.
Appears if the input voltage is 30 V
or greater (ac or dc), Also appears in
low-pass filter mode. Also appears in
cal, Hz, and duty cycle modes.

AutoHOLD is active.
Display HOLD is active.
Peak Min Max modes and the
response time is 250 μs.
MAX MIN
AVG
Minimum-maximum recording mode.
See Low-pass Filter.
1.800.561.8187info@Fluke-Direct.ca
Fluke-Direct.ca

Other manuals for Fluke 87V MAX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 87V MAX and is the answer not in the manual?

Fluke 87V MAX Specifications

General IconGeneral
WaterproofYes
Product typeDigital multimeter
Product colorYellow
Frequency range0.5 - 199.99 kHz
DC voltage range0.1 - 1000 V
Resistance range0.1 - 50 Ω
Capacitance range0.1 - 9999 nF
Measuring categoryCAT III 1000V
Placement supportedHandheld multimeter
Resistance resolution0.1 Ω
Resolution (frequency)0.01 Hz
Resolution (AC current)0.1 µA
Resolution (DC voltage)0.1 mV
Temperature measurement range-200 - 1090 °C
International Protection (IP) codeIP67
Battery life800 h
Battery typeAA
Power sourceBattery
Number of batteries supported3
Weight and Dimensions IconWeight and Dimensions
Depth215 mm
Width600 mm
Height101 mm
Weight698.5 g