Multimeters 
  Making Measurements   
 21 
Measuring Capacitance 
W Caution 
To avoid possible damage to the Meter or to 
the equipment under test, disconnect circuit 
power and discharge all high-voltage 
capacitors before measuring capacitance. 
Use the dc voltage function to confirm that 
the capacitor is discharged. 
The Meter's capacitance ranges are 10.00 nF, 100.0 nF, 
1.000 μF, 10.00 μF, 100.0 μF, and 9999 μF. 
To measure capacitance, set up the Meter as shown in 
Figure 6. 
To improve the accuracy of measurements less than 
1000 nF, use the relative (REL) mode to subtract the 
residual capacitance of the Meter and leads. 
Note 
If too much electrical charge is present on the 
capacitor being tested, the display shows 
“diSC". 
MIN MAX
RANGE
REL
Hz %
AutoHOLD
Peak MIN MAX
4½ DIGITS
1 Second
˚
C/
˚
F
OFF
mA
 A
mV
V
V
A
A
mA
COM
V
400mA
FUSED
10A MAX
FUSED
A
TRUE RMS MULTIMETER
87
V
LOLO
Select
Capacitance
+
+
+
+
+
+
+
+
+
 
aom10f.eps 