CERTIFIBER ENGLISH - 50
ments
Optical Measurements
+3dBm to -55dBm
.01dB resolution
±.25dB typical accuracy
Length
Maximum 2000m (6600ft)
1m (1ft) resolution
Delay
0 to 10,000 nS
1nS resolution
Cable Standards
TIA 568B
ISO 11801
Network Specifications
ATM - 155 ATM - 155 SWL ATM - 622
FDDI 100Base-F 10Base-FL
10Base-FB TokenRing FiberChannel
1000 BASE-SX 1000 BASE-LX
CERTIFIBER REMOTE
Physical Characteristics
Dimensions: 7.62 cm x 16.5 cm x 3.35 cm
(3.0" x 6.5" x 1.28")
Weight: 0.379kg (13.4oz)
Power Source
3 AA Alkaline batteries
Battery Life: Varies depending on usage and
battery quality. On average, the batteries will
support testing of well over 500 cables.
Environmental
Operating Temperature:to 45° C (32° to 113°F)
Storage Temperature:-10° to 55 ° C (14° to 131°F)
Operating Humidity (non-condensing): 5 to 90%
Storage Humidity: 5 to 95%