©Fluke Calibration 2011 Basics Of Measurement Uncertainty for DMM Calibration 27
Now, returning to the …
statement of uncertainty
• ... A measurement is complete only when
accompanied by a statement of the uncertainty of the
estimate. For example:
VDMM = 100.0051mV 0.0004 mV
• In this case, 0.0004 mV would be the resulting value
of U
m,
calculated as shown below: