Tests Run per Test Standard During an Autotest
C
C-3
Table C-1. Tests Run per Test Standard During an Autotest (continued)
Test Standard
1
Attenuation ACR Return Loss
Prop.
Delay
2
Delay
Skew
2
TIA Cat 5 Channel 1-100 MHz
TIA Cat 5 Basic Link 1-100 MHz
TIA Cat 4 Channel 1-20 MHz
TIA Cat 4 Basic Link 1-20 MHz
TIA Cat 3 Channel 1-16 MHz
TIA Cat 3 Basic Link 1-16 MHz
Fiber Optic (Loss)
ISO11801 EN50173 Class A 0.1 MHz
ISO11801 EN50173 Class B 0.1-1 MHz
ISO/IEC11801 Class C 1-16 MHz 1-16 MHz ■❒
ISO/IEC11801 Class D 1-100 MHz 1-100 MHz 1-100 MHz ■❒
ISO 11801 Class D - No RL 1-100 MHz 1-100 MHz ■❒
EN 50173 Class C 1-16 MHz 1-16 MHz ■❒
EN 50173 Class D 1-100 MHz 1-100 MHz 1-100 MHz ■❒
EN 50173 Class D - No RL 1-100 MHz 1-100 MHz ■❒
IEEE 10Base2
IEEE 10Base5
1.
2.
Test standards version 4.0.
Resistance, propagation delay, and delay skew are always measured; results appear on printed test
reports.
Pass/Fail result given.
Pass/Warning result given.
Results within the accuracy specifications of the test tool are marked with an asterisk.
NEXT test is run but not displayed. Results are used to calculate ACR.