HOL
D
3
2
1
5
7
6
200 A
CAT
1000 V
CAT 600 V
4
HOLD
200 A
CAT
1000 V
CAT 600 V
AUTO
SELECT
T6-1000
ELECTRICAL TESTER
5
2
7
3
1
4
6
Test Lead Assembly (T5-RLS) Replace
only with Fluke double-insulated leads
()
PN 4462973
TP1 Probe Set, Flat-Blade PN 648128
Battery Door PN 4944370
Battery Door Screw PN 1618579
Use only specied replacement parts
Quick Reference Guide
Model T6-1000 Model T6-600
Function
Requires
Test Leads
Range Range Resolution Accuracy
[1]
FieldSense
Voltage ac
No 1000 V 600 V 1 V
±(3 % + 3 counts)
45 Hz to 66 Hz
[2] [3]
FieldSense
Current ac
No 200.0 A 200.0 A 0.1 A
±(3 % + 3 counts)
45 Hz to 66 Hz
FieldSense
frequency (Hz)
No 45 Hz to 66 Hz 1 Hz ±(1 % + 2 counts)
[3]
Voltage ac Yes 1000 V 600 V 1 V
±(1.5 % + 2 counts)
45 Hz to 66 Hz
Voltage dc Yes 1000 V 600 V 1 V ±(1 % + 2 counts)
Resistance
Yes 2000 Ω 2000 Ω 1 Ω
±(1 % + 2 counts)Yes 20.00 kΩ 0.01 kΩ
Yes 100.0 kΩ 0.1 kΩ
[1] Accuracy: ±( [ % of reading] + [number of least signicant digits] ). Accuracy is specied for 1 year after calibration, at
18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are accoupled, RMS responding.
[2] Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves,
standing on an insulated ladder, or otherwise insulated from earth ground.
[3] FieldSense is specied from 16 V to 100 % of range.
Fork opening 17.8 mm
Temperature
Operating
Storage
-10 °C to +50 °C (+14 °F to +122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating
Storage
2000 m
10 000 m
Relative Humidity 0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2x AA (IEC LR6) 360 hr continuous, typical is 200 hr using the FieldSense function
Temperature coefcient 0.1 x (specied accuracy) / °C for <18°C or >28 °C (<64.4 °F or >82.4 °F)
T6-600/T6-1000
Electrical Tester
with FieldSense Technology
» See “Safety Information”.
Go to www.uke.com to register your product and nd more information, or
download this Quick Reference Guide in other languages.
PN 4897598 September 2017 Rev. 2, 11/17
© 2017 Fluke Corporation. All rights reserved.
Specications are subject to change without notication.
Fork Opening 17.8 mm
Overview
Wire Position
1 Wire Only
Finger Guard
For safe operation, hold the
Tester behind the nger guard.
Display
Model T6-1000
Model T6-600
X Hazardous Voltage ≥30 V
Function Selection/On/Off
Auto Off
15 min
FieldSense Ground Contact
Test Probes/Storage Dock
Symbols
W
WARNING. RISK OF DANGER. Test with fork and FieldSense ground contact.
»
Consult user documentation. Test with fork and ground probe.
Y
Hazardous voltage ≥30 V. Test with probes.
Battery full charge.
FieldSense Measurement: Fluke voltage/current
sensing technique.
Battery low. Replace.
J
Good earth ground connection.
Back light
J
No earth ground connection.
Specications
USA: 1-800-44-FLUKE (1-800-443-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566-5655
China: +86-400-921-08365
Anywhere in the world: +1-425-446-5500
● HT6 Belt Holster
● TPAK Hanger
● PRV240FS
● AC285 SureGrip™ Alligator Clips
● AC220 SureGrip™ Alligator Clips
Contact FlukeUSA:
.Lead Replacement
Accessories
● HT6 ●
Replacement Parts
Question and Answer IconNeed help?

Do you have a question about the Fluke T6-600 and is the answer not in the manual?

Fluke T6-600 Specifications

General IconGeneral
Battery life360 h
Battery typeAA
Number of batteries supported2
Control typeButtons, Rotary
Display typeLCD
Housing colorBlack, Grey, Red, Yellow
Jaw width (max)17.8 mm
AC current range- A
AC voltage range- V
Operating altitude0 - 2000 m
Storage temperature (T-T)-30 - 60 °C
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)0 - 90 %
Weight and Dimensions IconWeight and Dimensions
Depth43.8 mm
Width61.1 mm
Height259.3 mm
Weight350 g

Summary

Fluke T6 Electrical Tester Overview

Wire Position

Identifies the correct position of the wire within the fork opening for measurement.

Finger Guard

Explains the safety feature of holding the tester behind the finger guard.

Tester Display

Details the components and readings shown on the tester's digital display.

Hazardous Voltage Warning

Explains the indicator for detecting dangerous voltage levels.

Function Selection and Power

Describes how to select measurement functions and turn the device on/off.

FieldSense Ground Contact

Highlights the importance and location of the FieldSense ground contact.

Test Probes and Storage

Shows the test probes and their designated storage dock.

Product Specifications and Support

Symbols Explained

Clarifies the meaning of various symbols used in the manual and on the device.

Technical Specifications

Lists detailed electrical and environmental specifications for the T6 models.

Replacement Parts

Provides a list of necessary replacement parts for the tester.

Available Accessories

Details optional accessories that enhance the tester's functionality.

Contact Information

Offers contact details for customer support and inquiries.

Performing Electrical Measurements

Measuring Voltage and Frequency

Step-by-step guide for measuring AC/DC voltage and frequency using probes.

Measuring AC Current

Demonstrates how to measure AC current using the fork opening.

Measuring Resistance

Details the procedure for performing resistance measurements.

Using the HOLD Function

Explains the usage of the HOLD function to retain and display readings.

Low Battery Indicator

Shows the indicator for low battery status and its meaning.

FieldSense Technology Tips

FieldSense Measurement Display

Explains how FieldSense measurement appears when properly grounded.

Troubleshooting FieldSense Readings

Provides solutions for common issues affecting FieldSense readings.