PN 686953
March 1998 Rev.1, 9/01
1998-2001 Fluke Corporation. All rights reserved. Printed in U.S.A. Product names are trademarks of their respective companies.
T5-600/T5-1000
Electrical Tester
Service Information
Introduction
This service information sheet provides the following information for the T5-600 and T5-1000 Electrical
Testers (hereafter referred to as "the tester").
Safety information
Parts and service information
Specifications
Cleaning procedure
Required equipment
Performance tests
Parts and accessories list
Battery replacement procedure
For operating instructions, refer to the T5-600/T5-1000 Electrical Tester Instruction Sheet.
Safety Information
Warning
To avoid possible electric shock or personal injury, follow these guidelines:
Do not use the tester if it is damaged or operating abnormally. Protection
may be impaired.
Before each use:
Make sure the battery door is closed and latched.
Inspect the tester and test leads. Look for cracks, missing plastic, exposed
metal, or damaged insulation. Replace damaged test leads before using the
tester.
Verify the tester’s operation by measuring a known voltage.
Replace the batteries as soon as the low battery indicator (M) appears.
Do not use the tester around explosive gas, vapor or dust.
Do not apply more than the rated voltage, as marked on the tester, between
terminals or between any terminal and earth ground.
Refer servicing to qualified personnel.
Use caution when working above 30 V ac rms, 42 V ac peak, or 60 V dc.
When using the probes, keep your fingers behind the finger guards on the
probes.
Connect the common test lead before you connect the live test lead.
Disconnect the live test lead first.
The display will not display hazardous voltages in display hold. The voltage
indicator LED (
) continues to operate.
®
w ww. . com
information@itm.com1.800.561.8187

Other manuals for Fluke T5-600

Question and Answer IconNeed help?

Do you have a question about the Fluke T5-600 and is the answer not in the manual?

Fluke T5-600 Specifications

General IconGeneral
WaterproofYes
Product typeDigital multimeter
AC current range0 - 100 A
AC voltage range0 - 600 V
Resistance range0 - 1000 Ω
Battery voltage1.5 V
Dimensions (WxDxH)30.5 x 51 x 203 mm
Weight and Dimensions IconWeight and Dimensions
Weight300 g

Summary

Introduction

Safety Information

Parts and Service

Specifications

General Specifications

General technical details including calibration, voltage, temperature, and environmental ratings.

Resolution and Accuracy

Details on measurement resolution and accuracy for various functions.

Input Characteristics

Information on input protection and impedance for different functions.

General Specifications (Serial Numbers 79559999 and Below)

General specifications for testers with serial numbers below 79559999.

Cleaning the Tester

Instructions for safely cleaning the electrical tester.

Equipment Required for Performance Tests

Performance Tests

Testing the AC Current Function

Procedure for testing the AC current measurement capability.

Testing the Voltage Functions

Procedures for testing AC/DC voltage and HOLD functions.

Resistance and Continuity Function Tests

Tests to verify resistance and continuity measurement accuracy.

Low Battery Indicator Test

Procedure to verify the correct operation of the low battery indicator.

Parts and Accessories

Battery Replacement

Related product manuals