Appendices
Camera Specifications and Dimensions D
D-9
Table D-2. TiR3, TiR4, Ti55 and Ti50 Specifications (cont.)
Model Name
Ti55 and
TiR4 with
IR Fusion
Ti55 and
TiR4 without
IR Fusion
Ti50 and TiR3
with
IR Fusion
Ti50 and TiR3
without
IR Fusion
Temperature Measurement
Calibrated
Temperature
Ranges
Range 1 = -20 °C to 100 °C
(-4 °F to 212 °F)
Range 2 and 3 are not
available on the the TiR4
Range 2 = -20 °C to 350 °C
(-4˚F to 662˚F)
Range 3 = 250 °C to 600 °C
(482 °F to 1112 °F)
Range 1 = -20 °C to 100 °C
(-4 °F to 212 °F)
Range 2 is not available on the
TiR3
Range 2 = -20 °C to 350 °C
(-4 °F to 662 °F)
Accuracy ±2 °C or ±2 % Accuracy
Measurement
Modes
Movable points & boxes
Centerpoint
Cursor temp.
Center box (area min/max,
average)
Automatic hot and cold point
detection
Isotherm (only on models
without IR Fusion)
Color alarm (only on models
with IR Fusion)
Centerpoint
Cursor temp.
Center box (area min/max,
average)
Emissivity
Correction
Based on user input. Variable from 0.01 to 1.0 (0.01
increments)
Power
Battery Type Li-Ion Smart Battery, rechargeable, field-replaceable
Battery Oper.
Time
3 hours continuous operation