369
Appendix A: Reference Method
Names
Industry standards use different names for the three reference
methods. Tables A-1 and A-2 show the names used in this manual
and by four common standards.
Table A-1. Reference Method Names fore TIA Standards
Link End
Connections
Included in
Loss Results
Method
Name in
This
Manual
TIA-526-14-C
(multimode)
TIA-526-7-A
(single-mode)
2 connections 1 Jumper One-Cord
Reference
Method
(was Method B)
One-Cord
Reference Method
(was Method A.1)
1 connection 2 Jumper Two-Cord
Reference
Method
(was Method A)
Two-Cord
Reference Method
(was Method A.2)
None 3 Jumper Three-Cord
Reference
Method
(was Method C)
Three-Cord
Reference Method
(was Method A.3)