MPU Dispatch Check Procedure
_____________________________________________________________________
____________________________________________________________________
Page 18 of 28 PRD-0000022543 Rev .00D
MNKS008 0.0 (4/08)
5.3. Input Parameters
The table below identifies parameters required as input by the
DECA algorithms.
Object
number
ModBus
Address
Description Unit
570 1140 Calculated composition : Minimum avg.
mole weight
kg/mol
571 1142 Calculated composition : Maximum avg.
mole weight
kg/mol
572 1144 Mole Methane (C1) % mol
573 1146 Mole Nitrogen (N2) % mol
574 1148 Mole Carbon dioxide (CO2) % mol
575 1150 Mole Ethane (C2) % mol
576 1152 Mole Propane (C3) % mol
577 1154 Mole Water (H2O) % mol
578 1156 Mole Hydrogen sulphide (H2S) % mol
579 1158 Mole Hydrogen (H2) % mol
580 1160 Mole Carbon oxide (CO) % mol
581 1162 Mole Oxygen (O2) % mol
582 1164 Mole i-Butane (IC4) % mol
583 1166 Mole n-Butane (NC4) % mol
584 1168 Mole i-Pentane (IC5) % mol
585 1170 Mole n-Pentane (NC5) % mol
586 1172 Mole n-Hexane (NC6) % mol
587 1174 Mole n-Heptane (NC7) % mol
588 1176 Mole c-Octane (NC8) % mol
589 1178 Mole n-Nonane (NC9) % mol
590 1180 Mole n-Decane (NC10) % mol
591 1182 Mole Helium (HE) % mol
592 1184 Mole Argon (AR) % mol
593 1186 Mole Hexane+ (C6+) % mol
594 1188 Mole rest % mol
595 1190 Reference Temperature C
596 1192 Reference Pressure barA