4 PSU 0127- 7003313-16-19-20 15-04-2019
Declaration of conformity
We Foamico declare that this product is in conformity with the following directives:
- Machinery (2006/42/EG).
Safety
Attention! Use only original FOAMICO Nozzles, hoses, couplings and spare parts.
Precautionary measures
The construction of the system is in accordance with the generally adopted, technical requirements and the
stipulations concerning working environment and accident prevention. Therefore the equipment must be in
its best technical state before being used, and must only be utilized according to its requirements and by
observance of the precautionary measures and operational instructions. Disturbances, which might influence
the safety in particular, must be rectified immediately.
Appropriate utilization
FOAMICO low-pressure system is manufactured with the purpose of:
Rinsing with water, spreading foam and sanitizer within the stated boundaries.
Any other kind of application or use beyond this is considered to be inappropriate and deviant concerning
the requirements, and may lead to dangerous situations. FOAMICO is not liable for any sequential damages
brought about by this. Appropriate utilization includes the following:
The instructions, regulations, and recommendations given in this manual.
The observance of the prescribed intervals for inspection and maintenance.
The correct maintenance for good operational condition of the system.
The observance of the prescribed conditions for the environment and operation
2 Installation
SAFETY INSTRUCTIONS FOR MOUNTING AND INSTALLATION
IMORTANT!
Never install or apply damaged products. Claims concerning damages must be made to the carrier
immediately.
IMPORTANT!
Work in the connection with installations, start up, and maintenance on the Foamico cleaning systems should
only be done by authorized electricians, because the valid national regulations concerning prevention of
working accidents. (e.c. high voltage regulations: EN 60204, VBG4 DIN-VDE 0100/0113/0160) must be
respected. In cases of irregular installations there is a risk for major damages on both material and people.
Location and Mounting
The system should always be located in a frost-free room.
Stationary system must always be mounted where the surfaces are of solid quality, and when applicable the
fastening must always be done with the delivered bolts and raw plugs. Holes for wall brackets must be
drilled according the dimensional drawing.
The satellite should be connected to an adequate pipe system. This should correspond to distance from the
water supply, the maximum water flow and vertical distance from the boosting System. The pressure loss