5 PSU 0127- 7003313-16-19-20 15-04-2019
from the booster system to the satellite should be kept on a minimum. It is recommended to keep it under
1,50 bar.
It is recommended to install a strainer and a stop valve just before the mainstation. Use Foamico filters and
valves
Water Supply
ATTENTION! Connection to water supply should always be done in according to local or national
standards.
If the legislation in your country requests safeguards for reverse current, this must be provide for.
BEFORE mounting the system, the piping must be flushed with water in order to remove possible parts or
dirt.
AFTER mounting the system, flushing of the pipes must always be done with the system in “rinsing mode”,
in order to avoid any impurities in the injector system. Please keep rinsing until the rinsing nozzle shows an
invariable clean water jet coming out.
The water connection should be connected with the in POS. A, fig. 4.1 shown inlet.
For machines (7003312-15-18) with separate injector for concentrated chemicals The water connection
should be connected with the in POS. L, fig. 4.1
Air supply
ATTENTION! Connection to air supply should always be done in according to local or national standards.
ATTENTION! The cleaning system shall always have its own air supply system. Failure in the cleaning
system could accidentally lead to water and/or detergent can flow back in the air system. To avoid damage
on other installations. it is mandatory to make a separate air supply system for the cleaning equipment.
BEFORE mounting the system, the piping must be cleaned with air in order to remove possible parts or dirt.
The air should be connected to the inlet shown in POS B fig. 4.1
Supply of Detergent and sanitizer
ATTENTION! The handling and use of Detergent should always be done according to the local and national
standards.
BEFORE Mounting the system the pipes must be rinsed with water, in order to remove possible parts or dirt.
ATTENTION! The handling and connection should be done according to description from the Detergent
supplier.
The connection for disintegrated chemicals 1 should be connected with the in POS. J, fig 4.1 shown inlet.
The connection for disintegrated chemicals 2 should be connected with the in POS. K, fig 4.1 shown
inlet.
The connection for disintegrated chemicals 3 should be connected with the in POS. L, fig 4.1 shown
inlet.