9 PSU 0127- 7003313-16-19-20 15-04-2019
TROUBLESHOOTING
Fault
Cause
Action
No rinsing pressure.
Booster or main station not
started.
Start booster/or main station.
Too many users on the same
time.
Check maximum number of users.
The ball valve at the inlet of the
system is not opened.
Open the ball valve.
Unstable rinsing pressure.
Unoriginal rinsing nozzle with
too high water consumption is
used.
Change to master rinsing nozzle
observe technical data for model.
No foam
The turning handle POS.D fig.1
is not in the position “foaming"
Turn the handle into the position
“foaming”
Leaking pipeline for the
disintegrated chemicals
Check the pipeline for
disintegrated chemicals
Booster or pumping station for
disintegrated chemicals is
inactive
Activate the Booster or pumping
station
The Ball valve for the
disintegrated chemicals at the
inlet or outlet for the cleaning
hose is closed.
Open the ball valves for
disintegrated chemicals or the ball
valve at the outlet from at the
cleaning hose.
Suction filter above fluid level in
the chemical container.
Lead the suction filter underneath
the fluid level.
Schlechte Schaumqualität
Wrong product.
Change to a foam product.
Injector system is blocked by
chemical remains.
Injector system and water nozzle
in the injector must be
disassembled and cleaned.
Cleansing hose is damaged,
pinched or kinked.
Replace the cleansing hose
No compressed air to the system.
Open the air inlet to the system.
Unoriginal foam nozzle is
installed.
Change to original foam nozzle,
installed with white nozzle guard.
Insufficient air supply to the
system.
Min. 150 l/min. and max. 200
l/min. at 4-6 bars is requested.
Air pressure not set correct.
Is adjusted on the air regulation
valve to be 4-6 bars.