INSTALLATION AAND UUSER
INSTRUCTIONS
All iinstructions mmust bbe hhanded tto uuser ffor ssafekeeping
Revision A - 05/04
Country(s) of destination - GB/IE
FAN-FFLUE GGAS FFIRE
RANGE
BLENHEIM SSTYLE
ELEGANCE
LULWORTH
Focal Point Fires plc, Avon Trading Park, Christchurch, Dorset BH23 2BT
Tel: 01202 499330 Fax: 01202 499326
www.focalpoint.co.uk
e-mail: sales@focalpointfires.co.uk

Other manuals for Focal Point LULWORTH

Questions and Answers

  • C
    Crystal RussellAug 6, 2025
    Why does the pilot light on my Focal Point LULWORTH go out after lighting?
    • J
      judithramirezAug 6, 2025
      The pilot light might go out due to several reasons. There could be a severe restriction in the gas supply, a faulty thermocouple, a blocked pilot or lint gauze. The control knob might also be fouling the indicator plate. Clear any obstructions, replace the pilot unit if the thermocouple is faulty, clean out any blockages, ensure the control knob doesn't foul the indicator plate, or hold the control knob in for longer.
  • E
    elizabethandersonAug 11, 2025
    How to fix a Focal Point LULWORTH Indoor Fireplace when it sparks but the pilot light doesn't ignite?
    • H
      Hailey NicholsAug 11, 2025
      If your Focal Point Indoor Fireplace sparks but the pilot doesn't light, it could be due to several reasons: * No gas supply: Check that the isolators are open and the gas supply is on. * Pipework blockage: Clean out any blockages. * Air not fully purged: Re-purge the supply or wait longer. * Spark earthing to metalwork: Reset the gap correctly. * Blocked pilot: Clean it out internally.
  • L
    Laura BlakeAug 16, 2025
    What to do if my Focal Point LULWORTH Indoor Fireplace runs for a while and then shuts off?
    • J
      jessicajordanAug 16, 2025
      If your Focal Point Indoor Fireplace runs for a time and then cuts off, it could be due to a loose or faulty thermocouple, which needs to be rectified. Another cause could be a blocked pilot, which needs to be cleaned out. Also, dirt or lint in pilot aeration hole or on the lint gauze can cause this problem, so clean thoroughly.
  • J
    jenna54Aug 21, 2025
    What to do if my Focal Point LULWORTH Indoor Fireplace doesn't spark at the pilot?
    • K
      Kristen WilsonAug 22, 2025
      If your Focal Point Indoor Fireplace isn't sparking at the pilot, it could be due to a few reasons: the HT lead might be detached and needs refitting, a faulty piezo unit might need replacement, debris could be shorting out the electrode and needs cleaning, or the spark could be shorting to metalwork under the tray, requiring a check of the HT lead routing under the burner.
  • J
    Jessica HermanAug 27, 2025
    Why does the pilot flame shrink when my Focal Point LULWORTH is on high?
    • D
      David StevensAug 27, 2025
      If the pilot flame shrinks when the fire is on high, it could be due to poor gas flow. Check the pressure with the fire on high, and if the pressure is low, remove any restriction in the pipework or valve. Ensure all isolators are adequately sized and fully open and the meter pressure is adequate. Also, check if the firebox grommet seal is missing and rectify.
  • J
    Jennifer JensenAug 31, 2025
    Why does my Focal Point Indoor Fireplace smell when first lit or in use?
    • M
      Mr. Jason NorrisAug 31, 2025
      The smell from your Focal Point Indoor Fireplace when first lit or in use could be due to spillage occurring, so you should carry out a spillage test and rectify any problems. Another reason could be a missing firebox grommet seal, which needs to be rectified.

Summary

Important Notes

Appliance Data

Installation Requirements

Terminal Location

Site Requirements

Ventilation

Unpacking the Appliance

Component Checklist

Preparing for Installation

Outer Wall Aperture

Gas Supply Routes

Installation Method 1

Installation Method 2

Installation Method 3

Flue Preparation

Firebox and Burner Tray

Fitting the Fan Terminal

Gas Connection

Fuel Bed Layout

Coal Effect Option

Step-by-step guide for arranging the moulded coals on the burner tray.

Fuel Bed Layout

Pebble Effect Option

Step-by-step guide for arranging the ceramic pebbles on the burner tray.

Fitting the Decorative Frame and Front

Testing and Commissioning

Operating the Fire

Spark Failure

Setting Pressure

Spillage Monitoring System

Testing for Spillage

Briefing the Customer

Servicing

Cleaning the Ceramics

Dismantling the Burner Tray

Checking the Fan Assembly

Control Box Removal

Troubleshooting Guide

Fan fails to start

Troubleshooting steps for when the fan does not start.

Fan runs but cycles from high to low.

Diagnosing issues when the fan speed fluctuates between high and low.

Fan cycles high to low on windy days

Explains normal operation on windy days and potential issues.

Fan runs in correct sequence but will not pass spillage tests.

Addresses problems where the appliance fails spillage tests despite correct sequence.

Fan runs but pilot flame will not hold when control knob is released

Troubleshooting steps for a pilot flame that extinguishes when the control knob is released.

Pilot will not light

Guide to diagnose and fix issues preventing the pilot light from igniting.

Pilot shrinks when fire is turned to high

Explains pilot starvation when turning the fire to high setting.

Fan or fire cuts off when getting hot

Potential causes for the appliance shutting down due to overheating.

Fan constantly runs at high speed.

Advice on issues where the fan remains at high speed.

Focal Point LULWORTH Specifications