INSTALLATION & USER INSTRUCTIONS
All instructions must be handed to the user for
safekeeping.
MODELS COVERED BY THESE INSTRUCTIONS
ALVOR FULL DEPTH RADIANT
*
F500328
AURA FULL DEPTH RADIANT
*
F500055
BLENHEIM FULL DEPTH RADIANT
*
F500261
LULWORTH FULL DEPTH RADIANT
*
F500305
SOHO FULL DEPTH RADIANT
F500160
FINSBURY FULL DEPTH RADIANT
F500159
ARCH FULL DEPTH RADIANT
F500161
* AVAILABLE WITH MANUAL CONTROL ONLY
AVAILABLE WITH MANUAL OR SLIDE CONTROL
FULL DEPTH INSET GAS FIRE
Please note : Except where otherwise stated, all rights,
including copyright in the text, images and layout of this
booklet is owned by Focal Point Fires plc. You are not per-
mitted to copy or adapt any of the content without the
prior written permission of Focal Point Fires plc.
1
Revision A - 12/10
© 2010 Focal Point Fires plc.
LULWORTH
GB IE
Focal Point Fires plc.
Christchurch, Dorset BH23 2BT
Tel: 01202 499330
Fax: 01202 499326
www.focalpointfires.co.uk
e : sales@focalpointfires.co.uk
ALVOR AURA
ARCHFINSBURYSOHO

Questions and Answers

  • D
    dwhitneyAug 9, 2025
    Why does the pilot light on my Focal Point Indoor Fireplace go out after lighting?
    • T
      Theresa RomanAug 9, 2025
      The pilot light might go out due to several reasons. There could be a severe restriction in the gas supply, a faulty thermocouple, a blocked pilot or lint gauze. The control knob might also be fouling the indicator plate. Clear any obstructions, replace the pilot unit if the thermocouple is faulty, clean out any blockages, ensure the control knob doesn't foul the indicator plate, or hold the control knob in for longer.
  • D
    Denise ThompsonAug 14, 2025
    How to fix a Focal Point ALVOR Indoor Fireplace when it sparks but the pilot light doesn't ignite?
    • S
      Stuart MayAug 14, 2025
      If your Focal Point Indoor Fireplace sparks but the pilot doesn't light, it could be due to several reasons: * No gas supply: Check that the isolators are open and the gas supply is on. * Pipework blockage: Clean out any blockages. * Air not fully purged: Re-purge the supply or wait longer. * Spark earthing to metalwork: Reset the gap correctly. * Blocked pilot: Clean it out internally.
  • D
    Donald MillerAug 19, 2025
    What to do if my Focal Point ALVOR runs for a while and then shuts off?
    • A
      Amy BarrSep 12, 2025
      If your Focal Point Indoor Fireplace runs for a time and then cuts off, it could be due to a loose or faulty thermocouple, which needs to be rectified. Another cause could be a blocked pilot, which needs to be cleaned out. Also, dirt or lint in pilot aeration hole or on the lint gauze can cause this problem, so clean thoroughly.
  • D
    david25Aug 23, 2025
    What to do if my Focal Point ALVOR Indoor Fireplace doesn't spark at the pilot?
    • S
      Suzanne WellsAug 25, 2025
      If your Focal Point Indoor Fireplace isn't sparking at the pilot, it could be due to a few reasons: the HT lead might be detached and needs refitting, a faulty piezo unit might need replacement, debris could be shorting out the electrode and needs cleaning, or the spark could be shorting to metalwork under the tray, requiring a check of the HT lead routing under the burner.
  • A
    Amber RowlandAug 29, 2025
    Why does the pilot flame shrink when my Focal Point ALVOR is on high?
    • Y
      Yvonne NelsonAug 29, 2025
      If the pilot flame shrinks when the fire is on high, it could be due to poor gas flow. Check the pressure with the fire on high, and if the pressure is low, remove any restriction in the pipework or valve. Ensure all isolators are adequately sized and fully open and the meter pressure is adequate. Also, check if the firebox grommet seal is missing and rectify.
  • D
    David AllenSep 3, 2025
    Why does my Focal Point ALVOR Indoor Fireplace smell when first lit or in use?
    • C
      charrisSep 3, 2025
      The smell from your Focal Point Indoor Fireplace when first lit or in use could be due to spillage occurring, so you should carry out a spillage test and rectify any problems. Another reason could be a missing firebox grommet seal, which needs to be rectified.