INSTALLATION AND USER INSTRUCTIONS
All instructions must be handed to user for safekeeping
Revision C - 08/08
Country(s) of destination - GB/IE
PLASMA
CAPELLA
PLATINUM
FLUELESS GAS FIRE
Focal Point Fires plc, Christchurch, Dorset BH23 2BT
Tel: 01202 499330 Fax: 01202 499326
www.focalpointfires.co.uk
e-mail: sales@focalpointfires.co.uk
Question and Answer IconNeed help?

Do you have a question about the Focal Point PLASMA CAPELLA PLATINUM and is the answer not in the manual?

Focal Point PLASMA CAPELLA PLATINUM Specifications

General IconGeneral
Fuel TypeElectric
Remote ControlYes
ThermostatYes
TimerYes
Installation TypeWall Mount

Summary

Important Notes

Appliance Data

Installation Requirements

Room Sizing

Specifies the minimum room volume requirement of 30m³ for adequate air circulation and correct fire operation.

Site Requirements

Clearances to Non-Combustibles

Specifies minimum clearances to sides (100mm), front (500mm), ceiling (800mm), and floor (60mm) for non-combustible materials.

Clearances to Combustible Materials

Details clearances to combustible materials, fabrics, curtains, and furniture, including electrical equipment above.

Ventilation

Requires a minimum of 100 cm² ventilation, an openable window, and recommends specific vent types for draught reduction.

Unpacking the Appliance

Component Checklist

Lists the quantity and description of parts included with the appliance, such as firebox, instructions, and fixings.

Removing the Frame Assembly

Details how to disassemble the decorative fireframe assembly into its component parts for installation.

Gas Supply Routes

Preparing the Appliance

Fixing the Appliance

Guidance on securing the appliance to the wall, emphasizing wall strength, flatness, and avoiding blocking ventilation holes.

Checking the Burner

Final Fitting of the Frame Assembly

Testing and Commissioning

Operating the Appliance

Step-by-step instructions on how to light the pilot, operate the main burner at high and low settings, and turn the fire off.

Spark Failure

Information on the spark gap requirement and the consequence of piezo electric spark failure.

Setting Pressure

Procedure for checking and setting the burner pressure using a U gauge, and troubleshooting pressure issues.

Briefing the Customer

Servicing

Servicing the Burner Unit and Gas Assembly

Step-by-step guide for servicing the burner unit and gas assembly, including component removal and cleaning.

Pilot Assembly

Catalyst

Testing for Firebox Leakage

Troubleshooting Guide

Important Notes

Clearances to Combustibles

Ventilation and Room Size

Operating Instructions

Combustion Monitoring System

Cleaning

Servicing

List of Spare Parts