INSTALLATION & USER INSTRUCTIONS
All instructions must be handed to the user for
safekeeping.
MODELS COVERED BY THESE INSTRUCTIONS
BLENHEIM MULTIFLUE **
LULWORTH MULTIFLUE**
EXCELSIOR MULTIFLUE*
VOGUE *
AURA MULTIFLUE*
FINSBURY MULTIFLUE
SOHO MULTIFLUE
BI-FLAME*
* AVAILABLE WITH MANUAL CONTROL ONLY
AVAILABLE WITH MANUAL OR SLIDE CONTROL
*
* AVAILABLE WITH MANUAL, SLIDE CONTROL OR REMOTE CONTROL
MULTIFLUE/INSET GAS FIRE
Please note : Except where otherwise stated, all rights, including
copyright in the text, images and layout of this booklet is owned by
Focal Point Fires plc. You are not permitted to copy or adapt any of
the content without the prior written permission of Focal Point Fires
plc.
1
Revision C - 01/13
© 2013 Focal Point Fires plc.
GB IE
BS 7977-1 : 2009
BS EN 509 : 2000
KM579168
Focal Point Fires plc.
Christchurch, Dorset BH23 2BT
Tel: 01202 499330
Fax: 01202 499326
www.focalpointfires.co.uk
e : sales@focalpointfires.co.uk
IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE
Questions or problems with your appliance?
Don’t take it back to the store
just give us a call on 01202 588601 we’re here to help
lines open between 9am and 5pm, Monday to Friday
NOTE: VOGUE, BI-FLAME AND EXCELSIOR MODELS MAY BE SUPPLIED WITH DIFFERENT FIREFRONTS TO THOSE SHOWN
BLENHEIM
ELEGANCE
LULWORTH
AURA
FINSBURY SOHO

Questions and Answers

  • L
    Lisa SimpsonAug 6, 2025
    Why does the pilot light on my Focal Point AURA go out after lighting?
    • J
      Jamie HarmonAug 6, 2025
      The pilot light might go out due to several reasons. There could be a severe restriction in the gas supply, a faulty thermocouple, a blocked pilot or lint gauze. The control knob might also be fouling the indicator plate. Clear any obstructions, replace the pilot unit if the thermocouple is faulty, clean out any blockages, ensure the control knob doesn't foul the indicator plate, or hold the control knob in for longer.
  • M
    Michael JonesAug 11, 2025
    How to fix a Focal Point Indoor Fireplace when it sparks but the pilot light doesn't ignite?
    • C
      Cynthia AtkinsAug 11, 2025
      If your Focal Point Indoor Fireplace sparks but the pilot doesn't light, it could be due to several reasons: * No gas supply: Check that the isolators are open and the gas supply is on. * Pipework blockage: Clean out any blockages. * Air not fully purged: Re-purge the supply or wait longer. * Spark earthing to metalwork: Reset the gap correctly. * Blocked pilot: Clean it out internally.
  • V
    vmanningAug 16, 2025
    What to do if my Focal Point Indoor Fireplace runs for a while and then shuts off?
    • D
      Donna ColeAug 16, 2025
      If your Focal Point Indoor Fireplace runs for a time and then cuts off, it could be due to a loose or faulty thermocouple, which needs to be rectified. Another cause could be a blocked pilot, which needs to be cleaned out. Also, dirt or lint in pilot aeration hole or on the lint gauze can cause this problem, so clean thoroughly.
  • K
    Kimberly JohnsonAug 21, 2025
    What to do if my Focal Point AURA doesn't spark at the pilot?
    • J
      jamescampbellAug 21, 2025
      If your Focal Point Indoor Fireplace isn't sparking at the pilot, it could be due to a few reasons: the HT lead might be detached and needs refitting, a faulty piezo unit might need replacement, debris could be shorting out the electrode and needs cleaning, or the spark could be shorting to metalwork under the tray, requiring a check of the HT lead routing under the burner.
  • M
    Mike OrtegaAug 27, 2025
    Why does the pilot flame shrink when my Focal Point AURA Indoor Fireplace is on high?
    • P
      Paul WatsonAug 27, 2025
      If the pilot flame shrinks when the fire is on high, it could be due to poor gas flow. Check the pressure with the fire on high, and if the pressure is low, remove any restriction in the pipework or valve. Ensure all isolators are adequately sized and fully open and the meter pressure is adequate. Also, check if the firebox grommet seal is missing and rectify.
  • B
    Brandi ParkerAug 31, 2025
    Why does my Focal Point AURA Indoor Fireplace smell when first lit or in use?
    • J
      Jennifer RobbinsAug 31, 2025
      The smell from your Focal Point Indoor Fireplace when first lit or in use could be due to spillage occurring, so you should carry out a spillage test and rectify any problems. Another reason could be a missing firebox grommet seal, which needs to be rectified.

Summary

Installation Procedure Overview

Important Notes and Safety Precautions

Essential safety guidelines and general advice for installation.

Appliance Data and Specifications

Technical details and specifications of the gas fire appliance.

Installation and Site Requirements

Guidelines for fireplace opening, hearth, and site preparation.

Ventilation and Flue Box Installation

Requirements for ventilation and fitting prefabricated flue boxes.

Unpacking and Component Check

Procedures for unpacking the appliance and verifying all components.

Appliance Fitting and Gas Connection

Appliance and Opening Preparation

Steps for preparing the firebox, opening, and gas supply route.

Gas Supply Routing and Connection

How to route and connect the gas supply safely and correctly.

Installation Methods and Burner Fitting

Instructions for cable fixing installation and fitting the burner assembly.

Operation, Testing, and Safety Features

Fuel Bed and Firefront Installation

Guidance on correctly arranging fuel beds and fitting the firefront.

Operating the Fire Controls

Step-by-step instructions for operating manual, remote, and slide control models.

Testing and Safety System Checks

Procedures for spark gap, pressure checks, and flue spillage monitoring.

Customer Briefing and Final Checks

Instructions for briefing the customer and final safety checks.

Maintenance and Troubleshooting

Servicing and Cleaning Procedures

Recommendations for annual servicing and routine cleaning of the appliance.

Component Removal and Battery Replacement

Instructions for removing components and replacing batteries in control systems.

Troubleshooting Guide

Common issues, causes, and solutions for fire operation problems.

User Guide - General Information

Important User Notes and Safety

Essential safety advice and general operating principles for users.

Clearances to Combustibles

Guidelines on safe distances from combustible materials.

Fire Guards and Ventilation Requirements

Information on using fire guards and required ventilation for safe operation.

User Guide - Operation and Safety Systems

Operating the Fire - Manual Control

Detailed steps for operating the fire using manual controls.

Operating the Fire - Remote and Slide Controls

Instructions for operating the fire using remote and slide control systems.

Flue Spillage Monitoring System

Explanation of the flue spillage safety device and its function.

User Guide - Fuel Bed and Maintenance

Fuel Bed Layout Instructions

Guidance on correctly arranging fuel beds for different effects.

Servicing and Cleaning Procedures

Recommendations for annual servicing and routine cleaning of the appliance.

Replacing Batteries and Spare Parts

Steps for replacing batteries and a list of available spare parts.

User Guide - Support and Guarantee

Installation Details and Service History

Sections for recording installer details and service history.

Guarantee Terms and Conditions

Details of the product guarantee, terms, and claim procedures.

Focal Point AURA Specifications

General IconGeneral
Fuel TypeElectric
Voltage120V
Power Consumption1500W
Remote ControlYes
Width42 inches
Flame EffectLED
ThermostatBuilt-in
FinishBlack