INSTALLATION REQUIREMENTS
If the appliance is to be sited near a disused or unserviceable fireplace served by a natural draught flue then the
old flue must be sealed off. It will be necessary to ventilate the old flue to prevent condensation and dampness
forming, however any air vent used to ventilate the old flue must not be sited within 500mm of this appliance.
If the flue can be ventilated to the outside of the building then this is usually the best solution. If in doubt then
advice should be sought from a local building control officer. The appliance is designed to be wall mounted. If
the appliance is to be mounted on a newly fabricated area of wall that also serves the purpose of sealing off the
old flue then it is very important that there are no holes, gaps or otherwise in this wall that will allow draughts
from the old flue to enter the room, especially directly behind the appliance. Such draughts could affect the per-
formance of the ODS system and result in nuisance cutting out, for example. If the gas supply pipe is to enter
the appliance from the rear, i.e. emerge from the wall behind the appliance, then any hole in the wall from which
the pipe emerges must be tightly sealed.
ROOM SIZING
All Models : The room size should be a minimum of 23m
3
(e.g. 10’1” x 10’1” x 8’) to allow adequate circula-
tion of air and ensure the correct operation of the fire. This volume may include adjacent spaces but these
spaces must not be separated by a door. To calculate a room size in cubic metres (m
3
) divide the room vol-
ume in cubic feet (ft
3
) by 35.3.
SITE REQUIREMENTS
This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall.
This appliance may be installed in any room in the home except bathrooms or bedrooms. Installation in living
rooms is common, however other rooms such as kitchens, dining rooms and hallways are permitted, providing
a suitable natural gas supply is available, and rooms sizing and ventilation requirements are strictly adhered to
(see sections 3.1 and 4.1).
The appliance is designed to be versatile, and as such will operate correctly when exposed to normal gentle
draughts experienced within the home. It is not recommended, however that the appliance be installed in areas
where it is likely to be directly exposed to persistent strong draughts, that may be generated by outside doors,
windows, air vents, air conditioning units, extractor fans, ceiling fans etc. See section 4.1 for more information
on ventilation.
2
2.0
3.0
3.1
4.0
APPLIANCE DATA
Florence & Oxford models
Gas Group G20 Natural Gas CAT I2H
Inlet Pressure 20 mbar (+/- 2.0mbar)
Max Energy Input Gross 2.0 kW
Net 1.8 kW
Max Gas Rate 0.20 m3/h
Min Energy Input Gross 1.0 kW
Net 0.9 kW
Pilot Energy Input Gross 166 W
Net 150 W
Burner Pressure High 18.7 mbar. (+/-1.5 mbar). Hot
18.6 mbar. (+/-1.5 mbar). Cold
Low 4.1 mbar. (+/-0.75 mbar). Hot
4.0 mbar (+/-0.75 mbar). Cold
Main burner flow restrictor BM733/NGC6802A
Stereo 1.03mm (1/4” BSP)
Oxypilot SIT/Bray 9082
Gas Inlet Connection 8mm inlet restrictor elbow
Ignition Piezo spark
Spark Gap 4.0 mm (± 1.0mm)
APPLIANCE DATA
Purist & Serif models
Gas Group G20 Natural Gas CAT I2H
Inlet Pressure 20 mbar (+/- 2.0mbar)
Max Energy Input Gross 2.0 kW
Net 1.8 kW
Max Gas Rate 0.20 m3/h
Min Energy Input Gross 1.3 kW
Net 1.15 kW
Pilot Energy Input Gross 166 W
Net 150 W
Burner Pressure High 18.7 mbar. (+/-1.5 mbar). Hot
18.6 mbar. (+/-1.5 mbar). Cold
Low 7.4 mbar. (+/-0.75 mbar). Hot
7.3 mbar (+/-0.75 mbar). Cold
Gas Valve BM733/NGC6802A
Main burner flow restrictor Stereo 1.03mm (1/4” BSP)
Oxypilot SIT/Bray 9082
Gas Inlet Connection 8mm inlet restrictor elbow
Ignition Piezo spark
Spark Gap 4.0 mm (± 1.0mm)
Please see Data Badge affixed to appliance for current data.
This appliance is for use only with the gas type, and at the pressure stated on the appliance Data Badge.
©