STRUCTURAL REQUIREMENT
CAUTION
The support of the anchor plate (roof structure, slab, etc.) Must be sized in congruence with the fireplace static and
dynamic charges. The size calculation for the support is not the responsibility of focus or its affiliates. It is your
responsibility to consult with an engineer or architect for your project.
CONNECTOR
Connectors are all non-insulated chimney parts including focus flue, focus 8’’ universal adaptor and the chimney manufacturer
finishing collar with adapter.
To avoid heat traps the chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or
a floor, or ceiling.
Passage through an attic, roof frame floor, or ceiling must be done using an insulated chimney respecting all chimney
manufacturer clearances.
CAUTION
Passage through a wall or partition of combustible construction is not an appropriate installation for this
focus fireplace.
Refractory compound must be used to seal each connection.
FRESH AIR INTAKE
For optimum functioning, focus recommends a fresh air intake in the room (ideally under of the fire). We recommend
deflect-O A0684 semi rigid aluminium duct.
Minimum fresh air intake size:
This fresh air intake is compulsory
when operating venting appliances
such as kitchen hoods, permanent
air extractors or any appliances
creating an air depression in the
habitation.
IMPORTANT