6
45 cm
20 cm
20 cm
20 cm
16'' (US)
18''(Canada)
40 cm
45 cm
40 cm
16’’(US)
18’’(Canada)
45 cm
CLEARANCES TO COMBUSTIBLES
A. FLOOR PROTECTION
Rotating version require 16 inches (US) or 18 inches (Canada) of floor protection on all sides (360°).
Fixed version require 16 inches (US) or 18 inches (Canada) on the front and to extend 8 inches on the left and
right sides as well as for the back side.
Use of provided firebox insulator under the grate (vermiculite) is compulsory.
40 cm / 16’’ (US)
45 cm / 18’’ (Canada)
IMPORTANT
no radiant floor heating tubing under the fireplace !
pas de chauffage au sol !
non combustible surface R ≥ 0.6
surface non combustible R ≥ 0.6
combustible sub floor
sol combustible
minimum 8’
minimum 2.44 m
20’’
50 cm
33’’
84 cm
ROTATING VERSION
non-combustible
surface
R ≥ 0.6
FIXED VERSION
non-combustible
surface
R ≥ 0.6
B. CLEARANCES TO WALLS
CAUTION
The distance to a combustible wall must be maintained at 38 inches. Property damage or death can occur
if this distance is not maintained. Drywall products lined with paper such as sheetrock are combustible.
Clearances as indicated further apply.
Specifications