Unit operates at “FUZZY” mode or low level according to the actual humidity
environment. The unit operates at “FUZZY” mode when humidity is over 55%.
Compressor will turn on aer the “ON/OFF” buon is pressed in 3 minutes (Compressor
starts once the plug plugged in the socket aer 3 minutes). If the humidity is less
than 50%, unit will turn to operate in air clean mode and the compressor is off.
2. Unit operates connuously at ”LO” speed at low noise level with compressor
turns on unl water tank full or Power buon is pressed for off when the
humidity is more than 60%. Once the humidity is less than 55%, unit will turn to
operate at Air Clea
n mode. LCD shows as below:
3. Unit operates connuously at ”HI” speed with compressor turns on unl water
tank full or Power buon is pressed for off when the humidity is more than 45%.
Once the humidity is less than 40%, unit will turn to operate at Air Clean mode.
LCD shows as below:
4. Select “Air Clean” mode, unit operates at low fan speed and compressor turns off.
LCD shows as below:
5. Select “CONT” mode, unit operates connuously at high speed with compressor
turns on unl water tank is full or Power buon is pressed for off. LCD shows as
below:
4.
MODE
High
Medium
Low
MODE
High
Medium
Low
MODE
High
Medium
Low
MODE
High
Medium
Low