ELECTRICAL CONNECTIONS
EXTENSION LEADS
Before using any extension cord, make sure that the insulation is not cut or worn. Immediately repair or replace a
damaged or frayed cord.
ATTENTION :
Extension cords must be removed from the work area or located so that they will not get caught in parts, tools or other
objects while using the tool.
ELECTRICAL CONNECTION
Your planer thicknesser contains a precision electric engine. It must be connected on an electrical supply of 240V,
50 Hz. If your machine does not work when it is connected please check your electrical supply.
EARTHING INSTRUCTIONS
In case of malfunction or short circuit, grounding provides a path of least resistance for electric current to reduce the
risk of electric shock. This tool is equipped with an electric cord having an earthing conductor and a grounding plug.
The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local
codes and regulations.
Do not modify the plug provided. If it does not fit into the outlet, have a proper outlet installed by a qualified electrician.
Improper connection of the conductor grounded equipment can result in a risk of electric shock. The conductor with
insulation is green with or without yellow stripes is the conductor of grounding. If the repair or replacement of the
power cord is necessary, do not connect the grounding conductor to a live terminal.
If the earthing instructions are not completely understood, check with a qualified electrician or a person responsible
for maintenance, or if there is doubt properly grounding the tool.
If the power cable is damaged, it must be replaced by the manufacturer, after sales service or similarly qualified
persons in order to avoid a hazard. Do not operate the tool with a damaged power cable.
This tool is intended for use on an electrical circuit with a wall outlet and earthing pin.