38
RDSP Smpl Fault
The slave sample detection circuit is failed.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
ARM EEPROM Fault
The manager eeprom is fault.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
Meter Lost Fault
The communication between meter and inverter is interrupted.
Check if the communication cable between meter and inverter is correctly and
well connected.
BMS Lost
The communication between BMS and inverter is interrupted.
Check if the communication cable between BMS and inverter is correctly and
well connected.
Bms Ext Fault
The communication between BMS and inverter is interrupted.
Check if the communication cable between BMS and inverter is correctly and
well connected.
Bms Int Fault
DIP switch at the wrong position;
The communication between battery packs is interrupted.
Move the DIP switch to the correct position;
Check if the communication cable between battery packs is correctly and well
connected.
Bms Volt High
Battery over voltage.
Please contact battery supplier.
Bms Volt Low
Battery under voltage.
Please contact battery supplier.
Bms ChgCur High
Battery charge over current.
Please contact battery supplier.
Bms DchgCur High
Battery discharge over current.
Please contact battery supplier.
Bms Temp High
Battery over temperature.
Please contact battery supplier.
Bms Temp Low
Battery under temperature.
Please contact battery supplier.
BmsCellImbalance
The capacities of cells are different.
Please contact battery supplier.
Bms HW Protect
Battery hardware under protection.
Please contact battery supplier.