This inverter has an integrated export management function. To enable this function, a power meter or
CT must be installed. The CT should be clamped on the main live line of the grid side. The arrow on the
CT should be pointing towards the grid. The white cable connects to CT+, and the black cable connects
to CT-.
Meter/CT setting:
Short press the touch key to switch display or make the number+1. Long press the touch key to confirm
your setting.
If there is another generator in the home, CT2 can be used to record the power generated by the
generator and transmit the data to the website for monitoring.
Settings
Feature Parm
Meter/CT