TROUBLE SHOOTING
Cabinet does not
operate/start
The mains isolating switch on
the wall, circuit breaker or fuses
are off at the power board
Turn isolating switch circuit
breaker or fuses on
High pressure switch tripped
Switch cabinet off and on.
Clean condenser and radiator
Check gas pressure
Low pressure switch tripped
The power switch on the cabinet
is OFF
The power switch is faulty
Cabinet does not reach
correct temperature
Close drawer and re-test
temperature after thirty minutes
Ventilation grills are blocked
Vacuum or remove blockage
Evaporator coil fins blocked
Clean coil fins of food etc.
Thermostat needs adjustment
Ambient temperature > 25C
Adjust store air conditioning
Condenser radiator blocked
Replace Dixell controller
Temperature probe damaged
Replace temperature probe
Have defrost settings checked
Have fans checked/replaced
Excess external
condensation
Frame heating is not working
Check/replace power supply
Clean door tracks (see cleaning)
The table entries in italics indicate actions to be taken only by qualified Service
Personnel.