WARNING - ELECTRICAL PRECAUTIONS
All wiring, electrical connections, and system grounding must
comply with the National Electrical Code (NEC) and with any local
codes and ordinances. Employ a licensed electrician.
CAUTION
DO NOT OPERATE THIS PUMP DRY!
• Reviewinstructionsbeforeoperating.
SAFETY WARNINGS
BEFORE OPERATING OR
INSTALLING THIS PUMP, READ
THIS MANUAL AND FOLLOW
ALL SAFETY RULES AND
OPERATING INSTRUCTIONS.
CAREFULLY READ THESE SAFETY
MESSAGES IN THIS MANUAL AND ON PUMP.
SAFETY
APPLICATION
INSTALLATION
a) PUMP LOCATION:Thepumpshouldbeinstalledinaclean,
dryandventilatedlocationwhichprovidesadequatedrain-
age and room for servicing and protection from freezing
temperatures.Itshouldbebolteddownevenlyonagood
foundation,preferablyconcrete,topreventthedevelopmentof
unnecessarystress.Locatingthepumpascloseaspossible
tothesourceofwatersupplyreducesthefrictionlossesin
thesuctionpipeandprovidesformaximumcapacities.
b) SUCTION PIPE:
It is recommended that only new clean
pipeorhosebeusedandthesizebethesameasthatofthe
pumpsuctiontapping.Ifthepumpisinstalledanyappreciable
distanceawayfromthesourceofwatersupply,thesuction
pipeshouldbeincreasedbyonesize(thiswouldincreasethe
priming time). The suction pipe must always slope upwards
fromthewatersourcetothepumptoavoidairpocketsinthe
line.Incaseswherethepumphastobe reprime reprim
reprimedoftenanditisnotnecessarythatalotofwaterbe
delivered,itisadvisabletousea90°or45°elbowonthe
suctionline.Thisenablesthepumptoprimesoonerandalso
preventskinkingofthehose.Incaseswhereamaximum
volumeofwaterisrequiredoveraprolongedperiodoftime,
the suction line should be led almost horizontally to the
pump.Threadcompoundshouldbeusedonallpipejoints
andconnectionsshouldbethoroughlytightened.Astrainer
shouldbeconnectedtothebottomendofthesuctionpipe
anditshouldbewellsubmergedatalltimes.
c) WIRING:Itisrecommendedthataseparatecircuitbeused
fromthedistributionpaneltothepumpunit.Aproperlyfused
disconnectswitchistobeinstalledintheline,makingsure
thatthecorrectgaugeofcableisusedtocarrytheload.Very
longleadswillrequirealargercable.Anelectricianshould
beemployedtodothewiring.
Thispumpissuitableforinstallationswheretheverticaldistance
fromthepumptothewaterleveldoesnotexceed*25ft.(7.6m),
includingfrictionloss.Inoff-setinstallations,frictionlossesinthe
suctionpipemustbetakenintoconsideration.
*Varieswithelevationabovesealevel.
WARNING - RISK OF ELECTRICAL SHOCK
• Haveanelectricianprovideelectricalpowertothemotor.
• Motormustbegroundedandterminalcoverinplaceto
reduceelectricalshockhazard.
• Keepmotoroperatingareaasdryaspossible.
• Alwaysdisconnectpowerbeforeservicing.
• Notinvestigatedforuseinswimmingpoolareas.
FOR DUAL VOLTAGE MOTORS:
Voltage change instructions are locatedon motor label or on
wiringaccesscover.
Total Head in feet
20 30 40 50 55
CAPACITY IN U.S. GPM
54 43 31 11 3
Self-Priming Centrifugal
Utility Pump
Question and Answer IconNeed help?

Do you have a question about the Franklin Electric Red Lion RL-50 and is the answer not in the manual?

Franklin Electric Red Lion RL-50 Specifications

General IconGeneral
Voltage115/230V
MaterialCast Iron
Horsepower0.5 HP
Amperage9.8/4.9 amps
PhaseSingle

Summary

Safety Warnings

Do Not Operate Pump Dry

Do not operate the pump without water; review instructions before operating.

Electrical Precautions

Wiring and grounding must comply with codes; use a licensed electrician.

Dual Voltage Motors

Voltage change instructions are on the motor label or wiring access cover.

Application

Installation

Pump Location

Install in a clean, dry, ventilated location, preferably on a solid foundation.

Suction Pipe

Use clean pipe/hose of same size; slope upwards; use strainer.

Wiring

Use a separate circuit with fused disconnect; ensure correct cable gauge.

Operation - Priming the Pump

Priming

Fill pump casing with water before operating; replace plug.

Priming Under Pressure

Use check valve and air bleeder for priming under pressure.

Impeller Rotation

Impeller must rotate counter-clockwise when viewed from the front.

Starting the Pump

Never operate dry; may cause overheating or vapor lock.

Draining

Drain pump completely for freezing temperatures.

Maintenance

Lubrication

Pump requires no lubrication; refer to motor manufacturer for motor lubrication.

Replacing Mechanical Seal

Detailed steps for disassembling and reassembling the mechanical seal.

Maintenance Precautions

Check impeller rotation after assembly; do not remove shaft flinger.

Troubleshooting

Pump Fails to Prime or Primes Slowly

Common causes include suction line leaks, clogged lines, or insufficient water.

Reduced Pressure or Capacity

Issues like clogged impeller, suction line problems, or worn parts can reduce performance.

Limited Warranty