OWNER'S MANUAL
INLINE CONSTANT
PRESSURE SYSTEM
BEFORE YOU START
BEFORE INSTALLING PUMP, BE SURE TO READ
THIS OWNER’S MANUAL CAREFULLY.
REFER TO PRODUCT DATA PLATE(S) FOR
ADDITIONAL OPERATING INSTRUCTIONS AND
SPECIFICATIONS.
CAUTION
Keep work area clean, well-lit and uncluttered.
Keep safety labels clean and in good condition.
Wear safety glasses while installing or performing
maintenance on pump.
Adhere to the guidelines of the National Electric Code
(NEC) or Canadian Electric Code (CEC), and any other
state and local codes for ALL electrical installations.
Check with the appropriate agencies or contact a
licensed electrician.
Adhere to the guidelines of national, state and local
plumbing codes when installing this product. Check with
the appropriate agencies or water system professional
for additional information.
Most water system problems result from improper
installation. It is suggested that you read this manual
carefully before installing your pump.
The “TROUBLESHOOTING SECTION” will assist you in
locating and eliminating the cause of any trouble you
may encounter after installation. Check and make
available all the tools you will need to install your pump.
Required tooling may include wrenches, pipe sealant,
pipe ttings and nipples, screwdriver, etc. Be sure to
have available proper and adequate wiring material to
complete the installation correctly.
Hazardous voltage.
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor
or tank.
WARNING
Hazardous voltage.
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor
or tank.
WARNING
TERMINAL USING WIRE NO SMALLER THAN MOTOR CABLE
WIRES. TO REDUCE RISK OF ELECTRICAL SHOCK,
DISCONNECT POWER BEFORE WORKING ON OR AROUND
THE WATER SYSTEM. DO NOT USE INLINE SYSTEM IN
SWIMMING AREAS.
READ AND FOLLOW SAFETY INSTRUCTIONS
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential
for personal injury:
DANGER
warns about hazards that will cause
serious personal injury, death or major property damage
if ignored.
WARNING
warns about hazards that can cause
serious personal injury, death or major property damage
if ignored.
ATTENTION!
IMPORTANT INFORMATION FOR INSTALLERS
OF THIS EQUIPMENT!
THIS EQUIPMENT IS INTENDED FOR INSTALLATION BY
TECHNICALLY QUALIFIED PERSONNEL. FAILURE TO INSTALL
IT IN COMPLIANCE WITH NATIONAL AND LOCAL
ELECTRICAL CODES, AND WITHIN FRANKLIN ELECTRIC
RECOMMENDATIONS, MAY RESULT IN ELECTRICAL SHOCK
OR FIRE HAZARD, UNSATISFACTORY PERFORMANCE, AND
EQUIPMENT FAILURE. FRANKLIN INSTALLATION
INFORMATION IS AVAILABLE FROM PUMP MANUFACTURERS
AND DISTRIBUTORS, AND DIRECTLY FROM FRANKLIN
ELECTRIC. CALL FRANKLIN TOLL FREE 800-348-2420 FOR
INFORMATION.
WARNING
SERIOUS OR FATAL ELECTRICAL SHOCK MAY RESULT FROM
FAILURE TO CONNECT THE INLINE SYSTEM, METAL
PLUMBING, AND ALL OTHER METAL NEAR THE INLINE
SYSTEM OR CABLE, TO THE POWER SUPPLY GROUND

Questions and Answers

  • K
    Karen MorganAug 2, 2025
    What to do if my Franklin Electric SubDrive Inline 1100 is overheated?
    • S
      stewartshawnAug 2, 2025
      If your Franklin Electric DC Drives is overheated, it may be due to several reasons. The ambient temperature might be too high (exceeding 104°F or 40°C), there could be improper ventilation, or the heat sink might be clogged. Shield the drive from direct sunlight and ensure the air temperature around it doesn't exceed 104°F (40°C). Also, remove any debris from the heat sink fins to improve ventilation.
  • A
    Anthony WongAug 6, 2025
    Why my Franklin Electric DC Drives shows undervoltage?
    • S
      Sally MillerAug 6, 2025
      Undervoltage in your Franklin Electric DC Drives typically occurs because the line voltage is low (less than approximately 190 VAC) or due to misconnected input power leads. Check the incoming power connections and correct or tighten them if necessary to resolve the issue.
  • T
    Teresa ClarkAug 10, 2025
    What to do if Franklin Electric DC Drives shows short circuit?
    • D
      Desiree LynchAug 10, 2025
      If your Franklin Electric DC Drives indicates a short circuit immediately after powering up, it could be due to a defective cable, motor, or the drive itself. Check the motor connections and consider replacing the drive or motor to resolve the issue.
  • S
    Stephen FernandezAug 14, 2025
    What to do if Franklin Electric SubDrive Inline 1100 shows over pressure?
    • R
      Roberto TorresAug 15, 2025
      If your Franklin Electric DC Drives shows an overpressure error, it could be due to a few reasons: the shut-off sensor might have loose connections or has opened, the tank might be waterlogged, or the pressure setting is too close to the shut-off sensor pressure. Check for loose connections on the shut-off sensor and drive terminal blocks. Check the tank recharge, as a waterlogged tank may cause a pressure spike. Reduce the system pressure setting to a value less than the pressure shut-off sensor.
  • A
    albertwrightAug 19, 2025
    What to do if Franklin Electric SubDrive Inline 1100 DC Drives pump is locked?
    • A
      arielmosesSep 12, 2025
      If your Franklin Electric DC Drives pump is locked, it could be due to a dragging motor or pump, or abrasives/debris within the pump. Check the pump for external damage, such as a dent in the shell. Flush debris from the pump and consider adding an input screen to prevent future blockages.
  • A
    alanboyleAug 23, 2025
    How to fix motor underload on Franklin Electric SubDrive Inline 1100?
    • D
      Dr. Maurice DavilaAug 25, 2025
      A motor underload on your Franklin Electric DC Drives can occur if the pump is running dry due to no water, insufficient water in a cistern application, or an air/gas lock in the pump. Check the water source to ensure it's adequate. Restrict the pump discharge to prevent cavitation and raise the minimum water level in the cistern if applicable.
  • P
    parkerjessicaAug 27, 2025
    What to do if Franklin Electric SubDrive Inline 1100 DC Drives shows open motor circuit?
    • J
      Justin WalkerAug 27, 2025
      If your Franklin Electric DC Drives indicates an open motor circuit, it's likely due to a loose motor connection. Check the motor connection to ensure the wires are properly connected.

Summary

Installer Warnings and Safety Information

Safety Instructions and Alert Symbols

Understand safety alert symbols (DANGER, WARNING, CAUTION) and signal words for potential hazards.

Electrical Safety Precautions

General System Safety Guidelines

Inline System Key Features

Installation Procedures and Guidelines

System Location Requirements

Guidance on choosing a suitable, protected, and accessible location for the pump installation.

Plumbing and Piping Recommendations

Best practices for suction and discharge lines, pipe sizing, and fittings to minimize friction loss.

Pressure Tank Setup and Pre-charge

Details on pressure tank size, placement, and pre-charge settings for optimal pressure regulation.

Typical Installation Diagram Overview

Explanation of a graphical representation of a typical Inline System installation setup.

Wiring Installation Procedure

Step-by-step guide for connecting electrical power and ensuring proper wiring compliance.

System Operation and Priming

Pump Priming and Starting

Essential steps for filling the system with water and starting the pump correctly.

Handling Leaky Systems and Pressure Drop

Explains how the system manages leaky pipes and potential pressure variations.

Adjusting the Pressure Sensor

Procedure for setting the desired system pressure by adjusting the pressure sensor.

Optimizing Pump Demand vs. Supply

Process to ensure the pump receives adequate water supply to meet system demand and avoid cavitation.

Drive DIP Switch Configuration

Explains the function of DIP switches for underload sensitivity and steady flow adjustments.

Maintenance and Replacement Parts

Lubrication and Draining Procedures

Instructions for pump lubrication using water and draining the system for maintenance or freezing conditions.

Replacement Parts Identification

Identifies various parts of the Inline System and their corresponding part numbers or identifiers.

Troubleshooting Guide

Performance and Friction Loss Data

Inline System Performance Curves

Graphical representation of the system's performance characteristics under various flow and pressure conditions.

Friction Loss Tables

Data tables showing friction loss per 100' of pipe for different pipe sizes and flow rates.

Limited Warranty Information

Franklin Electric SubDrive Inline 1100 Specifications

General IconGeneral
Output Power1.1 kW
Power SupplySingle-phase
Enclosure RatingNEMA 3R
Protection FeaturesOverload, Over Temperature, Short Circuit
Ambient Temperature-10°C to 50°C
Humidity5% to 95% non-condensing
AltitudeUp to 1000 meters
Storage Temperature-20°C to 70°C (-4°F to 158°F)

Related product manuals