SubDrive Connect Plus
QUICKSTART GUIDE
English
EN
QUICKSTART GUIDE
Physical Installation
Environmental Requirements
The drive is intended for operation in ambient temperatures from -13 °F to 122 °F (-25 °C to 50 °C). Use the
following recommendations when selecting a location to mount the drive:
The drive should be mounted on a structure such as a wall or post
capable of supporting the weight of the unit, at least 18” (45.7 cm) off
the ground.
The drive electronics are air-cooled. Allow at least 6 inches (15.24 cm)
of clearance on each side and below the unit for air flow.
The mounting location should have nearby access to an appropriate
electrical supply and to the motor wiring. Refer to
Electrical Installa-
tion” on page 3.
Special Considerations for Outdoor Use
The drive is suitable for outdoor use with a NEMA 3R rating; however, the
following considerations should be made for outdoor installations:
The unit must be mounted vertically with the wiring end oriented
downward, and the cover must be properly secured (also applies to
indoor installations).
Mount the drive on a back plate 6” (15.cm) larger than the outer
dimensions of the enclosure in order to maintain the NEMA 3R rating.
NEMA 3R enclosures are capable of withstanding downward-directed
rain only. Protect from hose-directed or sprayed water as well as
blowing rain. Failure to do so may result in controller failure.
Install away from direct sunlight or locations subject to extreme temperatures or humidity.
Pressure Tank Sizing
A VFD system needs only a small pressure tank to maintain constant pressure, although a larger tank may
be used. The pressure tank pre-charge setting should be 70% of the targeted system pressure.
Risk of damage to drive
, or malfunction can occur due to improper handling,
installation, or environment.
Install in a location where temperature is within the range of product rating.
Mount VFD vertically (top up) for proper heat dissipation.
Do not mount VFD in direct sunlight or near other heat sources.
Do not install in corrosive environments.
Installation of non-approved screening may damage the drive and/or reduce output.
Cold Air
6 in mín.
(15.25 cm)
Warm Air
6 in mín.
(15.25 cm)
6 in mín.
(15.25 cm)
6 in mín.
(15.25 cm)
(
Maximum Pump Flow Minimum Tank Size
10 GPM 2 gallons (7.6 liters)
20 GPM 4 gallons (15.1 liters)
30 GPM 4 gallons (15.1 liters)
40 GPM 8 gallons (30.3 liters)
Over 40 GPM 20 gallons (75.7 liters)

Questions and Answers

  • D
    David RubioAug 4, 2025
    What to do if Franklin Electric DC Drives show overcurrent or locked pump?
    • K
      Kevin MendezAug 4, 2025
      If your Franklin Electric DC Drives display an overcurrent or locked pump error, it could be due to several reasons. The motor or pump might be locked, leading to amperage exceeding SFL at 30 Hz. Abrasives in the pump can also cause this issue, requiring you to remove and repair or replace the pump as needed. Additionally, excessive motor cable length can contribute to this problem; reduce the motor cable length, adhering to the Maximum Motor Cable Length table.
  • D
    donald38Aug 15, 2025
    What to do if Franklin Electric DC Drives motor is underload?
    • L
      Luis LopezAug 15, 2025
      If the Franklin Electric DC Drives motor is underload, it could be due to several factors. The well might be over-pumped, with the frequency near maximum and the load less than the configured ULD sensitivity. The system could be drawing down to the pump inlet, indicating it's out of water. Alternatively, a high static, light loading pump may be the cause; consider resetting for less sensitivity if the pump is not out of water. Verify the pump rotation and reconnect if necessary for proper rotation. If the pump is air/gas locked, set it deeper in the well to reduce this issue.
  • J
    joneslisaAug 25, 2025
    Why Franklin Electric SubDrive Connect Plus SDCP-SUB2043 DC Drives show undervoltage?
    • S
      sandra55Aug 25, 2025
      If Franklin Electric DC Drives show an undervoltage error, it could be due to low line voltage. Check the incoming power connections and correct or tighten them if necessary. Ensure the incoming voltage is correct by checking the breaker or fuses and contacting the power company if needed.

Summary

Wiring Guidelines

Fuse;Circuit Breaker and Wire Sizing

Table detailing required fuse/breaker sizes and wire gauge for different cable lengths.

Conduit Locations and Sizing

Incoming Power Supply Testing

Procedures for testing incoming voltages before connecting the drive.

DIP Switch Settings

Basic Setup (DIP SW1 - Position 1)

Configures recognition of DIP switch settings or enables mobile app programming.

Menu Settings

Operational Setpoints

Configure maximum current, primary/secondary setpoints, and drawdown pressure.

System Response Configuration

Troubleshooting

Diagnostic Fault Codes

Lists fault codes, possible causes, and corrective actions for drive issues.

Safety Information

General Safety Warnings

Highlights risks of electrical shock, injury, and damage during installation and operation.

Product Specific Precautions

Details specific safety measures for VFDs, including high voltage and ESD precautions.

Franklin Electric SubDrive Connect Plus SDCP-SUB2043 Specifications

General IconGeneral
Input Voltage200 - 240 VAC
Horsepower2 HP
EnclosureNEMA 3R
Control MethodSensorless Vector Control
Enclosure RatingNEMA 3R
Humidity95% non-condensing
Maximum Operating Temperature50°C
Power SupplySingle-Phase AC
Power Range2 HP
Protection FeaturesOverload, Short Circuit, Over Temperature
Communication InterfaceModbus RTU
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Altitude1000 m