Fill pump with water before starting. Inspect pump for shipping damage and report immediately to dealer.
Understand signal words (Danger, Warning, Caution) with the safety alert symbol for potential personal injury.
Installation by qualified personnel required. Electrical shock/fire hazard if codes not followed. Grounding is critical.
Keep accurate records of installation details like date, model, well depth, wire size, motor, and control box information.
Check pump and components before installation. Ensure power supply matches motor/control box. Make electrical connections.
Three-phase motors require magnetic starters with quick-trip, ambient compensated heaters of correct size.
Fasten cable to drop pipe every 10 ft. Use safety cable and torque arrestor. Use Schedule 40/80 pipe as needed.
Install check valve above pump. Install additional valves every 100 ft. for deeper settings. Consider REMOVABLE poppet valve.
Follow instructions enclosed in the cable splicing kit you purchase for connecting the submersible pump cable.
Keep pump 5' from bottom, above screens. Place sanitary well seal or pitless adapter. Ensure adequate flow over motor.
Employ licensed electrician. Follow codes. Ensure power supply matches motor/control box. Grounding and arrestors are key.
Diagrams show typical wiring for 2-wire (internal components) and 3-wire (requires control box) single-phase pumps.
Three-phase pumps require magnetic contractors with 3-leg protection. Figure 4 shows typical wiring diagram.
Check pump/well performance before final connection. Test for clear water, sand, and correct flow rate vs. well yield.
Protect pump from over-pumping by using sensors, floatless controls, flow control valves, or smaller pumps.
Install check valve upstream from pressure switch. Install pressure relief valve and pressure tank as recommended.
Protect pump from contact, currents, debris. Ground fault circuit interrupter advisable. Support pump at 15° slant.
Covers pump start failure, no water delivery, reduced output, frequent cycling, overloads, and rapid pressure switch cycles.
Warrants products free of defects for 1 year from installation or 2 years from manufacture. Does not cover corrosive liquids.
Warranty excludes damage from misuse, accident, or improper installation. Freight/reinstallation costs are purchaser's.
Warranty grants specific legal rights. Limitations on implied warranties and consequential damages may apply.