P a g e | 11 of 20
FREMCO A/S
ELLEHAMMERVEJ 14 | DK9900 FREDERIKSHAVN, DENMARK | VAT NO.: DK30815416
TELEPHONE +45 7230 1213 | SALES@FREMCO.DK | WWW.FREMCO.DK
NB: Too high clamping force can cause fiber damage.
After every fiber blowing deployment job, the clamping
force has to be reset to 1. This secures a longer life of
the machine.
Knob Position
Clamping Force N
1
14
2
18
3
22
4
25
5
29