12. RUNNING THE FIBER BLOWING MACHINE
Mount the
charged battery
and open the
machine.
1
Mount adaptor
plates (if not
already mounted).
See detailed
mounting guide in
section
“Photo Guide
Changing
Adaptor Plates”
2
3
Close the lid and
lock it with the
lever. Check that
the fiber is not
stuck and runs
smoothly in the
machine by lifting
the support wheel
and pulling the
fiber a little back
and forth.
4
When fiber safety is
activated, the display
shows FIB OFF.
Press ON to continue
if needed.
To reset the counter
for a new job, switch
off the machine and
then on again on the
main switch.
8
NB: Each fiber blowing job is different, depending on fiber, duct,
quality of compressed air, blowing length, weather conditions etc.
Lift the support
wheel and push the
fiber in between the
wheels, approx.15
cm. Release the
support wheel to let
it fall into place,
thus fixing the fiber
between the
wheels. Check that
the fiber is placed
correctly in the
grooves of the
wheels. Mount the
duct in over the
fiber and into the
adaptor plate.
3
2
6
Set speed, torque and
clamping force
(pictures 5 and 6).
Start with low values
for both speed, torque
and clamping force,
and gradually in-
crease to a suitable
level.
The machine has two
fiber protection
systems torque
limitation and
spinning protection.
Both systems will
protect the fiber from
damage, independent
of speed and torque
settings.
5
Please see the section
on Fiber Protection on
page 7 for further
information.
Turn on the Main
power switch. Press
ON switch to start
running the machine.
If you press ON
again, the machine
stops.
If you press Step, the
machine keeps
running as long as
you actuate the
switch.
7