Like the adaptor plates, the inlet guides are not
identical. One is for the top and one is for the
bottom.
Like the adaptor plates, the inlet guides must be
at least 0.2 mm larger than the fiber. Example: If
the fiber is 1.1 mm, choose
1.3 mm inlet guides.
Click the inlet guides into position at top and
bottom.
The machine is now ready for use.