Fresenius Medical Care 2008K User Manual

Fresenius Medical Care 2008K
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
2008K Hemodialysis Machine
Operator’s Manual
P/N 490042 Rev P

Table of Contents

Other manuals for Fresenius Medical Care 2008K

Questions and Answers:

Fresenius Medical Care 2008K Specifications

General IconGeneral
ManufacturerFresenius Medical Care
Model2008K
TypeHemodialysis Machine
Dialysate Flow Rate300-800 mL/min
Arterial Pressure MonitoringYes
Venous Pressure MonitoringYes
Power Supply50/60 Hz
Ultrafiltration Rate0-4000 mL/h
DisplayLCD
Safety FeaturesBlood leak detection, air detection, pressure monitoring, temperature monitoring, conductivity monitoring
Conductivity Range13.0-16.0 mS/cm

Summary

Introduction and Safety

About this Manual and Operator Requirements

Overview of the manual's purpose, organization, and operator qualifications.

General Warnings and Safety Precautions

Essential safety warnings for machine operation, concentrates, and environment.

Chapter 1 Machine Overview and Components

Machine Function and Organization

Explains the machine's purpose, how it works, and its overall layout.

Control Panel and its Sections

Details the control panel, its sections, and key components.

Blood and Dialysate Circuits

Describes the blood and dialysate flow paths and controls.

Machine Modules

Explains the function of key modules like blood pump and level detector.

Chapter 2 Preparation, Testing, and Parameter Setting

Daily Preparation and System Setup

Steps for daily machine setup before patient connection.

Connecting and Priming the Blood Circuit

Procedures for connecting bloodlines and priming the circuit.

Machine Testing and Final Set-Up

Performing pressure and alarm tests before dialysis.

Setting Treatment Parameters

General guidance on setting patient-specific parameters.

Dialysate, Concentrate, and Conductivity Settings

Configuring dialysate composition and conductivity limits.

Ultrafiltration, SVS, and Heparin Administration

Setting UF profiles, SVS, and heparin delivery.

Test Options and Blood Pressure Settings

Configuring tests, options, and blood pressure monitoring.

Chapter 4 Monitoring Treatment and Alarms

Monitoring Treatment Screens (Home, Trends, Kt/V)

Using screens to monitor treatment progress and effectiveness.

Pressure and Blood Parameter Monitoring

Monitoring arterial, venous, and transmembrane pressures.

Power Failure, Completion, and Maintenance Procedures

Handling power failures and completing dialysis.

Disinfection and Maintenance Procedures

Cleaning, disinfection, and routine maintenance tasks.

Alarms and Troubleshooting Overview

Understanding alarms, warnings, and troubleshooting steps.

Appendices and Glossary

Appendix A: Single Needle Dialysis

Setup and operation for optional single needle dialysis.

Appendix B: Concentrates, Options, and Specifications

Concentrate types, software options, and machine specifications.

Appendix C: 2008K@home Differences

Compares the 2008K and 2008K@home models.

Glossary

Definitions of key terms used in the manual.