Friax RSF2 - Menu Table; Menu Parameters User Factory Values (from 1 to 11)

Default Icon
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C1
tAmb U1 1
thum U2 2
humr U3 3
tCon U4 4
Tele U5 5
C2
rcon U1 1
reva U2 2
r ch U3 3
rhGr U4 4
r cP U5 5
r rc U6 6
C3
FanC U1 1
FanE U2 2
C4
CtP U1 1
Fet U2 2
Fct U3 3
Cht U4 4
C5
End
01 InIt rF
02 Hour 12h 12h
24h
0
12h AM/PM 1
03 Hr
04 dEG °C °C
°C
0
°F 1
05 OFF1 0 0
-5 °C à +5 °C
-9 °F à +9°F
06 * OFF2 0 0 -20 à 20%
07 dFSE 12 12
08 FstY 0 0
0
1
2
09 StbY OFF OFF
10 rst No No
11 End
17
Menu Table
Menu Parameters User factory values (from 1 to 11)
Read-only menu Monitoring
Exit from the user menu takes place 30 seconds after the last user action.
This menu is intended for reading the output states of the card and the analog readings of the probes.
It is mainly intended for installers to have information on the operation
of the air conditioner0
This menu is primarily intended for the user for basic air conditioner settings.
setting
TEXT CONFIG 1
CONFIG
2
Désignation Setting range Comment
User Settings Menu
Paring remote control with regulator
Time display
Time setting (hour + minute)
Unit of measurement T°
S1 ambient temperature probe calibrati
o
Adjustment by 0.1
S2 hygrometry probe calibration
Setting by 5
Fan speed correction
evaporator in GV
Position from 1 to 20
Setting by1 (steps of
0,3 V)
Fan status in neutral zone
0: Stopping ventilation
PV: low speed
GV: high speed
Activation of Standby mode
On or Off
Split card reset + Remote control
Yes (long press OK 3sec) or No
Exit User Settings Menu
AFSS menus TEXT
under menu
Number Désignation Displayed value range
After-sales service menus - Access without code by Menu MONI with long press OK 3sec
Cellar probe temperature (NTC 10k ambient)
Cellar probe temperature (SHT sensor)
Cellar humidity probe (SHT sensor) % and Err display if fault
Condenser probe temperature
Remote control probe temperature
Condenser relay status
Evaporator relay status
Heating relay status
Triac humidity status
Compressor relay status
Crankcase resistance relay status
Fan voltage Condenser
Evaporator fan voltage
Total compressor operating time from 0h to 65535 simple display without adjustment
Total evaporator fan operating time from 0h to 65535 simple display without adjustment
Total condenser fan operating time from 0h to 65535 simple display without adjustment
Cellar resistance operating time from 0h to 65535 simple display without adjustment
°C / °F and Err display if fault
Exit from the monitoring menu after 5 minutes after the last user action with an RF refresh of data
every 3 seconds within this menu.
°C / °F and Err display if fault
°C / °F and Err display if fault
°C / °F and Err display if fault
On or OFF
On or OFF
On or OFF
On or OFF
On or OFF
On or OFF
from 0 à 100 (step of 0,1V)
from 0 à 100 (step of 0,1V)